Part Number List

Results 1
Models table for series Compact Fan Type Ionizer ER-Q
Part No.DatasheetCE Marking Compliant DirectivesCharge Removal TimeIon balanceSupply voltageCurrent consumptionDischarge methodDischarge output voltageMax. fan speedMax. fan volumeMain functionsIndicatorsOzone generationAmbient TemperatureAmbient HumidityVibration resistanceGrounding methodMaterialWeight (Typ.)Accessories
EMC Directive, RoHS Directive
1.5 sec. approx. (plus or minus1,000V to plus or minus100V)
(Note:Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.)
plus or minus10 V or less
(Note: Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.)
24 V DC plus or minus10%
200 mA or less
High-frequency AC method
plus or minus2 kV approx.
6.4 m/s
(Note:Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.)
0.2 m3/min
Discharge check, Discharge error, Fan error, Check output, Error output
Discharge (DSC): Green LED, Alarm (ALARM): Red LED
0.02 ppm or less
(Note:Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉
35 to 65% RH (No dew condensation allowed), Storage: 35 to 65% RH
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
C (capacitor) grounding
Enclosure: PBT, Discharge needle: Tungsten
Net weight: 110 g approx.
Connector for wiring: 1 set
[Manufactured by MOLEX: Housing (5557-08P), Terminal (5556T)]