Part Number List

Results 2
Models table for series Fan Type Ionizer ER-F
Part No.DatasheetCE Marking Compliant DirectivesCharge Removal TimeIon balanceSupply voltageCurrent consumptionDischarge methodDischarge output voltageMain functionsIndicatorsOzone generationAmbient TemperatureAmbient HumidityGrounding methodMaterialWeight (Typ.)AccessoriesRemark
EMC Directive, RoHS Directive
1 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC ±10%
700 mA or less
High-frequency AC method
± 2 kV approx.
Error output, Discharge halt input
Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
0.04 ppm or less
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage : -10℃ to +65℃ +14℉ to +149℉
35% RH to 65% RH (No dew condensation allowed),
Storage : 35% RH to 65% RH
C (capacitor) grounding
Enclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC
New weight : 790 g approx.
Straight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc.
(Note): The discharge needle unit is loaded on the straight louver before shipment.
If not specified, the ambient temperature for measurement is +20℃ +68℉.
EMC Directive, RoHS Directive
1.5 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC ±10%
400 mA or less
High-frequency AC method
± 2 kV approx.
Error output, Discharge halt input
Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
0.04 ppm or less
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage : -10℃ to +65℃ +14℉ to +149℉
35% RH to 65% RH (No dew condensation allowed),
Storage : 35% RH to 65% RH
C (capacitor) grounding
Enclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC
New weight : 790 g approx.
Straight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc.
(Note): The discharge needle unit is loaded on the straight louver before shipment.
If not specified, the ambient temperature for measurement is +20℃ +68℉.