Static Control Devices: Pulse AC Method Area Ionizer ER-X

Model List

Found 12 matches. Display 1 - 12 matches.
Part No.sort descendingData SheetCE marking compliant directivesEffective charge removal widthCharge removal timeIon balanceDischarge methodDischarge frequencyDischarge output voltageOzone generationMaximum air pressureApplicable fluidParts Inventory
   Column active Filter
Close

Filter by CE marking compliant directives

Column active Filter
Close

Filter by Effective charge removal width

Column active Filter
Close

Filter by Charge removal time

Column active Filter
Close

Filter by Ion balance

Column active Filter
Close

Filter by Discharge method

Column active Filter
Close

Filter by Discharge frequency

Column active Filter
Close

Filter by Discharge output voltage

Column active Filter
Close

Filter by Ozone generation

Column active Filter
Close

Filter by Maximum air pressure

Column active Filter
Close

Filter by Applicable fluid

 
design engineersPanasonicER-X032HC
EMC Directive, RoHS Directive320 mm
12.598 in
approx.
1 sec. or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method30 Hz
(Note: Set the discharge frequency to 30 Hz. Do not use any other frequency.)
±7,000 V approx.0.01 ppm or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
0.1 MPaAir (dried clean air)
(Note:The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).)
design engineersPanasonicER-X001
EMC Directive, RoHS Directive50 mm 1.969 in approx.0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2)
(Note 1: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and air supply 60 ℓ / min. (0.3 MPa)) .
(Note 2: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method
(Note:The discharge frequencies of 50 Hz, 20 Hz are accepted.)
50 Hz / 20 Hz±7,000 V approx.0.01 ppm or less
(Note:Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.)
0.5 MPaAir (dried clean air)
(Note:The dried clean air is the air dried (dew point: equivalent of -20 ℃ -4 ℉) and filtered (mesh-size: equivalent of 0.01 μm) .)
design engineersPanasonicER-X008
EMC Directive, RoHS Directive80 mm 3.150 in approx.1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
plus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Pulse AC method50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz±7,000 V approx.0.01 ppm or less0.5 MPaAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 degrees ) and filtered (mesh-size: equivalent of 0.01 micro m) air.)
design engineersPanasonicER-X008HC
EMC Directive, RoHS Directive80 mm
3.150 in
approx.
1 sec. or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method30 Hz
(Note: Set the discharge frequency to 30 Hz. Do not use any other frequency.)
±7,000 V approx.0.01 ppm or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
0.1 MPaAir (dried clean air)
(Note:The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).)
design engineersPanasonicER-X048
EMC Directive, RoHS Directive480 mm 18.898 in approx.1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
plus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Pulse AC method100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz
(Note: The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)
±7,000 V approx.0.01 ppm or less0.5 MpaAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.)
design engineersPanasonicER-X064HC
EMC Directive, RoHS Directive640 mm
25.197 in
approx.
1 sec. or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method30 Hz
(Note:Set the discharge frequency to 30 Hz. Do not use any other frequency.)
±7,000 V approx.0.01 ppm or less
(Note:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
0.1 MPaAir (dried clean air)
(Note:The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).)
design engineersPanasonicER-XC02
EMC Directive, RoHS Directiven/an/an/an/an/an/an/an/an/a
design engineersPanasonicER-X016
EMC Directive, RoHS Directive160 mm 6.299 in approx.1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
plus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Pulse AC method100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz
(Note: The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)
±7,000 V approx.0.01 ppm or less0.5 MpaAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.)
design engineersPanasonicER-X016HC
EMC Directive, RoHS Directive160 mm
6.299 in
approx.
1 sec. or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method30 Hz
(Note: Set the discharge frequency to 30 Hz. Do not use any other frequency.)
±7,000 V approx.0.01 ppm or less
(Note:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
0.1 MPaAir (dried clean air)
(Note: The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).)
design engineersPanasonicER-X032
EMC Directive, RoHS Directive320 mm 12.598 in approx.1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
plus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Pulse AC method100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz
(Note:The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)
±7,000 V approx.0.01 ppm or less0.5 MpaAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.)
design engineersPanasonicER-X048HC
EMC Directive, RoHS Directive480 mm
18.898 in
approx.
1 sec. or less
(Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
±30 V or less
(Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
(Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.)
Pulse AC method30 Hz
(Note: Set the discharge frequency to 30 Hz. Do not use any other frequency.)
±7,000 V approx.0.01 ppm or less
(Note:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.)
0.1 MPaAir (dried clean air)
(Note:The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).)
design engineersPanasonicER-X064
EMC Directive, RoHS Directive640 mm 25.197 in approx.1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
plus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Pulse AC method100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz
(Note: The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)
±7,000 V approx.0.01 ppm or less0.5 MpaAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.)