Part Number List

Results 96
Models table for series Micro-size Inductive Proximity Sensor GXL
Part No.DatasheetCE Marking Directive ComplianceMax. operation distanceStable sensing rangeStandard sensing objectHysteresisRepeatabilitySupply voltageCurrent consumptionOutputOutput:Utilization categoryOutput:Short-circuit protectionMax. response frequency2-Color IndicatorEnvironmental resistance:Pollution degreeProtectionAmbient TemperatureAmbient HumidityVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceSensing range variation:Temperature characteristicsSensing range variation:Voltage characteristicsMaterialNet weightAccessoriesCableCable ExtensionOperation indicator
EMC Directive, RoHS Directive
5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 20 g approx.
-
EMC Directive, RoHS Directive
5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 20 g approx.
-
0.2 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long (Note:The bending-resistant cable type (model No. with suffix “-R”) has a 0.15 mm2 (GXL-15 type: 0.2 mm2) bending, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long.)
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
EMC Directive, RoHS Directive
5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 20 g approx.
-
EMC Directive, RoHS Directive
8 mm 0.315 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 20 g approx.
MS-A15F(Aluminum sheet): 1 pc.
EMC Directive, RoHS Directive
5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PET
Indicator part: Polyarylate
Net weight: 20 g approx.
-
Red LED(lights up when the output is ON)
EMC Directive, RoHS Directive
5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PET
Indicator part: Polyarylate
Net weight: 20 g approx.
-
EMC Directive, RoHS Directive
2.5 mm 0.098 in plus or minus 20%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.8 mm 0 to 0.071 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 12 g approx.
MS-GXL8-4(Sensor mounting bracket): 1 set
0.2 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long (Note:The bending-resistant cable type (model No. with suffix “-R”) has a 0.15 mm2 (GXL-15 type: 0.2 mm2) bending, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long.)
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Red LED(lights up when the output is ON)
EMC Directive, RoHS Directive
2.5 mm 0.098 in plus or minus 20%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.8 mm 0 to 0.071 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 12 g approx.
MS-GXL8-4(Sensor mounting bracket): 1 set
Red LED(lights up when the output is ON)
EMC Directive, RoHS Directive
2.5 mm 0.098 in plus or minus 20%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.8 mm 0 to 0.071 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 12 g approx.
MS-GXL8-4(Sensor mounting bracket): 1 set
EMC Directive, RoHS Directive
8 mm 0.315 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance(with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
Incorporated
1 kHz
3 (Industrial environment)
IP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
Enclosure: PBT
Indicator part: Polyarylate
Net weight: 20 g approx.
MS-A15F(Aluminum sheet): 1 pc.
Red LED(lights up when the output is ON)