Introducing the New Contact-Type Digital Displacement Sensor featuring the optical absolute method in the slim and strong unit body.  Developed to meet the needs of the production floor, this high-precision, slim Sensor unit features a robust sensor head, while the controller offers a diversity of functions.

Features:

  • Slim body measuring 0.433 x 0.709 x 3.327 inches for easy installation even in a side-by-side arrangement
  • Class-top robustness in the industry
  • High accuracy in Class
  • Resolution of 0.1 μm 0.004 mil and indication accuracy of 1 μm 0.039 mil or less
  • Absolute value scale reading for elimination of “value skipping” and “unset zero point”

 

Part Number List

Results 15
Models table for series Contact-Type Digital Displacement Sensor HG-S
Part No.DatasheetCE Marking Directive ComplianceEnvironmental resistance : ProtectionEnvironmental resistance : Ambient temperatureEnvironmental resistance : Ambient humidityInsulation resistanceEnvironmental resistance : Vibration resistanceEnvironmental resistance : Shock resistanceMaterialWeight (Typ.)Remark.Compatible Sensor HeadNumber of connectable unitsSupply voltageCurrent consumptionAnalog Current OutputControl outputs(Output 1, Output 2, Output 3)Control outputs(Output 1, Output 2, Output 3):Short-circuit protectionControl outputs(Output 1, Output 2, Output 3):Judgment outputControl outputs(Output 1, Output 2, Output 3):Alarm outputExternal inputs (Input 1, Input 2, Input 3)External inputs (Input 1, Input 2, Input 3):Trigger inputExternal inputs (Input 1, Input 2, Input 3):Preset inputExternal inputs (Input 1, Input 2, Input 3):Reset inputExternal inputs (Input 1, Input 2, Input 3) Bank input A / BResponse timeDigital displayDisplay resolutionDisplay rangeContamination levelElevationEnvironmental resistance:Voltage withstandabilityCableNotesApplicable ControllerPosition detection methodMeasuring rangeTravel (mm)Measuring force : Downward mountMeasuring force : Upward mountMeasuring force : Side mountResolutionSampling rateIndication accuracy(P-P)Tip deviation amountHot swap functionOperation indicatorMounting nut tightening strengthProbe tightening torqueGrounding methodAccessory
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
140 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 7‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
60 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-
-
-
-
-
-
-
-
-
-
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
-
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP67 (IEC)
(Note): Excludes damage and deterioration to rubber bellows due to external causes.
-10 to +55 ℃ +14 to +131 ℉
(No condensation or icing),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each
1,960 m/s2acceleration in X, Y and Z directions three times each
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe: Ceramic, Rubber bellows: NBR (black)
※The probes (optional) are also available.
Net weight: 80 g approx.
(Note):Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
Optical absolute linear encoder method
10 mm 0.394 in
10.5 mm 0.413 in or more
1.65 N or less
1.10 N
(Note 1): When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
(Note 2): Typical value near center of measurement.
1.35 N or less
0.85 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
1.50 N or less
0.95 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
0.1 μm 0.004 mil
1ms
Full range: 1.0 μm 0.039 mil or less
Narrow range: 0.5 μm 0.020 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
35 μm 1.378 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.
Incorporated
2-color LED (Orange / Green)
12.5N・m
0.1 to 0.4 N・m (no force applied to main unit)
Capacitor grounding
Standard type (HG-S1010 / HG-S1110): Sensor head fastening wrench 1 pc., Mounting nut 1 pc.
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
140 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 7‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 6‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
140 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.2 mm2 2-core cable (brown and blue lead wires) / 0.15 mm2 7‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010(R)、HG-S1110(R)、HG-S1032
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
24 V DC ±10 %, including ripple 0.5 V (P-P)
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 6‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
EMC Directive, RoHS Directive
IP67 (IEC)
(Note): Excludes damage and deterioration to rubber bellows due to external causes.
-10 to +55 ℃ +14 to +131 ℉
(No condensation or icing),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 150 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each
1,960 m/s2acceleration in X, Y and Z directions three times each
Body: Aluminum, Holder: Stainless steel, Spindle: Free-cutting steel, Probe: Ceramic, Rubber bellows: NBR (black)
※The probes (optional) are also available.
Net weight: 150 g approx.
(Note):Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
Optical absolute linear encoder method
32mm 1.260 in
32.5 mm 1.280 in or more
2.97 N or less
1.90 N
(Note 1): When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
(Note 2): Typical value near center of measurement.
2.09 N or less
1.19 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
2.53 N or less
1.50 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
0.5 μm 0.020 mil
1ms
Full range: 3.0 μm 0.118 mil or less
Narrow range: 2.0 μm 0.079 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
40 μm 1.575 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.
Incorporated
2-color LED (Orange / Green)
12.5N・m
0.1 to 0.4 N・m (no force applied to main unit)
Capacitor grounding
Sensor head fastening wrench 1 pc., Mounting nut 1 pc.