Part Number List

Results 2
Models table for series Communication Unit for Digital Displacement Sensors SC-HG1
Part No.DatasheetCE Marking Directive ComplianceCompatible ControllersSupply voltageCurrent consumptionCommunication MethodSynchronization methodCommunication ProtocolCommunication SpeedElectrical characteristicsNumber of connectable units : Host (RS-485)Number of connectable units : SensorsStop bit lengthParity checkData bit lengthDegree of pollutionOperating altitudeEnvironmental resistance : ProtectionEnvironmental resistance : Ambient temperatureEnvironmental resistance : Ambient humidityVoltage withstandabilityInsulation resistanceEnvironmental resistance : Vibration resistanceEnvironmental resistance : Shock resistanceMaterialTotal extension distanceWeight (Typ.)RemarkNumber of connectable unitsRemote station typeNumber of occupied stationStation No. settingBaud Rate / Maximum Overall Cable DistanceCommunication Cable
EMC Directive, RoHS Directive
HG-SC□
24 V DC ±10 %, Ripple (P-P) 10 % or less (Within specified power supply voltage range)
(Note): Power is supplied from a connected master controller.
40 mA or less
Two-wire half duplex communication
Start-stop synchronization
MODBUS (RTU / ASCII) / MEWTOCOL-COM
1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps
Complies with EIA RS-485
1 to 99 units when MODBUS (RTU/ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-485 unit
1 bit / 2 bits
Even / Odd / None
8 bits (RTU) / 7 bits (ASCII)
2
2,000 m 6561.68 ft or less
(Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ 14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Communication cable : 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC
Net weight : 75 g approx., Gross weght : 120 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: ambient temperature +20 ℃ +68 ℉.
EMC Directive (Note), RoHS Directive
(Note): If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]".
HG-SC□
24 V DC ±10 %, Including ripple 0.5 V (P-P)
(Note): Power is supplied from a connected controller / master controller.
80 mA or less
Switchable CC-Link Ver.1.10 or 2.00
2
2,000 m 6561.68 ft or less
(Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ +14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Net weight : 80 g approx., Gross weight : 130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows : ambient temperature +20 ℃ +68 ℉.
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit
Remote device station
CC-Link Ver.1.10 : 4 stations, CC-Link Ver.2.00 : Switchable 2 or 4 stations
1 to 64 (0 and 65 or more : Error)
・10 Mbps/100 m 328.084 ft
・5 Mbps/160 m 524.934 ft
・2.5 Mbps/400 m 1,312.336 ft
・625 kbps/900 m 2,952.756 ft
・156 kbps/1,200 m 3,937.008 ft
Specified cable (shielded twisted cable)
(Note): Use only a special-use communication cable that is approved by the CC-Link Partner Association.

What's New