Part Number List

Results 20
Models table for series Compact Multi-voltage Photoelectric Sensor NX5
Part No.DatasheetCE Marking Directive ComplianceSensing rangeSensing objectHysteresisRepeatability(perpendicular to sensing axis)Supply voltagePower consumptionOutputOutput:Output operationResponse timeOperation indicatorStability indicatorPower indicatorSensitivity adjusterAutomatic Interference Prevention FunctionPollution degreeProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceEmitting ElementEmitting element:Peak emission wavelengthMaterialCableCable ExtensionAccessoryWeight (Typ.)
Low Voltage Directive, EMC Directive, RoHS Directive
0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
-
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
RF-230 (Reflector): 1 pc.
Low Voltage Directive, EMC Directive, RoHS Directive
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
-
Low Voltage Directive, EMC Directive, RoHS Directive
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
-
Low Voltage Directive, EMC Directive, RoHS Directive
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
-
Emitter: 125 g approx
Receiver: 140 g approx
Low Voltage Directive, EMC Directive, RoHS Directive
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
-
Emitter: 125 g approx
Receiver: 140 g approx
Low Voltage Directive, EMC Directive, RoHS Directive
0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
-
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
RF-230 (Reflector): 1 pc.
140 g approx.
Low Voltage Directive, EMC Directive, RoHS Directive
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Adjusting screwdriver: 1 pc.
Low Voltage Directive, EMC Directive, RoHS Directive
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Adjusting screwdriver: 1 pc.
140 g approx.
Low Voltage Directive, EMC Directive, RoHS Directive
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Adjusting screwdriver: 1 pc.
Low Voltage Directive, EMC Directive, RoHS Directive
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
IP66 (IEC)
-20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
(Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between power supply and output terminals
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
660 nm 0.026 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc