Part Number List

Results 34
Models table for series Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100
Part No.DatasheetCE Marking Directive ComplianceType of pressureRated pressure rangePressure withstandabilityApplicable FluidSupply voltageCurrent consumptionAnalog Voltage OutputProtectionAmbient TemperatureAmbient HumidityVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceTemperature characteristicsPressure portMaterialConnecting methodCableCable ExtensionWeight : Net weightWeight : Gross weightAccessoriesRemarkSet pressure rangePower consumptionSensor head supply voltageComparative OutputComparative Output: Output OperationComparative Output: Output ModesComparative Output: HysteresisComparative Output: RepeatabilityComparative Output: Response TimeComparative Output: Short-Circuit ProtectionAnalog OutputInputs : Sensor head inputInputs : External input (Auto-reference function/Remote zero-adjustment function)DisplayDisplay : Displayable pressure rangeOperation indicatorCable LengthWeight (Typ.)
EMC Directive, RoHS Directive
Gauge pressure
0 to +1.000 MPa
1.5 MPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M5 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
0 to +1.000 MPa
1.5 MPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M5 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
0 to -101.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M3 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
NPN open-collector transistor (2 outputs)
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and 0 V)
・Residual voltage : 2 V or less (at 100 mA sink current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +0.4 V DC or less
OFF voltage : +5 to +30 V DC, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M5 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
0 to -101.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M5 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
R1/8 male thread + M5 female thread.
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 10 g approx. / Cable 40 g approx.
80 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
0 to -101.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
R1/8 male thread + M5 female thread.
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 10 g approx. / Cable 40 g approx.
80 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
NPN open-collector transistor (2 outputs)
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and 0 V)
・Residual voltage : 2 V or less (at 100 mA sink current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +0.4 V DC or less
OFF voltage : +5 to +30 V DC, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
500 kPa
Air, non-corrosive gas
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
Output voltage : 1 to 5 V (over rated pressure range)
Zero point : within 1 V ± 2.5 % F.S. (vacuum / positive pressure type)
within 3 V ± 3 % F.S. (compound pressure type)
Span : within 4 V ± 3.5 % F.S.
Linearity : within ±0.5 % F.S.
Output impedance : 1 kΩ approx.
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉
M3 male thread (for installing gasket)
Front case : PBT, Rear case : PBT (glass fiber reinforced), Pressure port : Stainless steel (SUS303), O-ring : NBR
Pressure element : Silicon diaphragm, PPS
Connector
0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable)
Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable.
Head 6 g approx. / Cable 40 g approx.
70 g approx.
Connector (e-CON) : 1 pc.
Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
The sensor head can be used independently.