Specifications table for model FT-R60Y
ItemPerformance characteristics
Sensing ModeThru-beam type
Fiber TypeSquare head type
Fiber Head DiaM6
Fiber Head LengthW10 x H11 x D21.2 mm
With SleeveNo
Beam DirectionTop-view
Beam Axis Dia. / Spot Diameterdia. 3.5 mm
Fiber Cable Length2 m
Allowable Bending RadiusR4 mm
Free-CutAvailable
Semi-Custom Not available
Mounting LensNot available
ApplicationsOil-resistant
Environmental Resistance: ProtectionIP68G
Environmental Resistance: Ambient Temperature (Max.)80 degrees
Environmental Resistance: Ambient Temperature (Min.)-55 degrees
Sensing Range (STD)2,100 mm 82.677 in (FX-500 series)
Sensing Range (HYPR)3,600 mm 141.732 in (FX-500 series)
Sensing Range (U-LG)3,600 mm 141.732 in (FX-500 series)
Sensing Range (Long)3,600 mm 141.732 in (FX-500 series)
Sensing Range (Fast)1,260 mm 49.606 in (FX-500 series)
Sensing Range (H-SP)400 mm 15.748 in (FX-500 series)