Specification

Specifications table for model FT-V23
ItemPerformance characteristics
Sensing ModeThru-beam type
Fiber TypeSleeve type
Fiber Head Diadia. 2 mm
Fiber Head Length15 mm
With SleeveYes
Sleeve Diameter dia. 1 mm
Sleeve Length20 mm
Beam DirectionSide-view
Beam Axis Dia. / Spot Diameterdia. 0.75 mm
Fiber Cable Length2 m
Allowable Bending RadiusR4 mm
Free-CutAvailable
Mounting LensNot available
Mounting Protective TubeNot available
ApplicationsGeneral-purpose
Environmental Resistance: ProtectionIP30
Environmental Resistance: Ambient Temperature (Max.)80 degrees
Environmental Resistance: Ambient Temperature (Min.)-55 degrees
Sensing Range (STD)450 mm 17.717 in (FX-500 series)
Sensing Range (HYPR)1,800 mm 70.866 in (FX-500 series)
Sensing Range (U-LG)1,000 mm 39.370 in (FX-500 series)
Sensing Range (Long)880 mm 34.646 in (FX-500 series)
Sensing Range (Fast)280 mm 11.024 in (FX-500 series)
Sensing Range (H-SP)90 mm 3.543 in (FX-500 series)

Stock Check