Communication Unit for CC-Link SC-GU2-C

This module contributes to wire-saving, construction-saving, traceability, preventive maintenance and more. As the life cycle of equipment shortens year by year, controlling the cost at manufacturing or during usage has become an important subject. Panasonic uses the communication unit for CC-Link, SC-GU2-C.

Part Number List

Results 3
Models table for series Communication Unit for CC-Link SC-GU2-C
Part No.DatasheetApplicable Sensor AmplifierNumber of Connectable UnitsSupply Voltage Current ConsumptionAllowable Passing CurrentCommunication MethodNumber of Occupied StationBaud Rate / Total Extension LengthCommunication CableStation No. SettingRemote Station TypeAmbient TemperatureAmbient HumidityMaterialWeight (Typ.)AccessorySignal Channel No.Power Indicator Cable: TypeCable: Sheath Outer DiameterCable: LengthCable: Tensile Strength
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less (By power supplied from the SC-GU2-C.)
Max. 25 mA or less (when all indicators light up)
(Note) The current consumption and input current of output device connected are not included.
-10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45 degrees +14 to +113degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -10 to +70 degrees +14 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 %
Enclosure: Heat-resistant ABS
Net weight: 20 g approx.
Gross weight: 40 g approx.
Connector (e-CON): 1 pc.
Green LED (lights up when the power is ON)
Sensor amplifiers (NPN output type) that can connect to non-line connector CN-70 (optional) (FX-500/300/311/410 series, LS-401/403, DPS-401/402, GA-311)
(Note) Only the below models respond to data communication.
FX-501/502, FX-301/305, LS-403, DPS-401/402
Max. 16 units (Sensor amplifiers / input units) (Maximum of 12 units including the FX-500 Series can communicate optically)
24 V DC +10-15 % Ripple P-P 10 % or less
110 mA or less (excluding connected sensor amplifiers / input units)
Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2)
(Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
(Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current.
CC-Link Ver.1.10
Switchable 1 or 4 station
10 Mbps / 100 m 328.084 ft
5 Mbps / 150 m 492.126 ft
2.5 Mbps / 200 m 656.168 ft
625 kbps / 600 m 1968.504 ft
156 kbps / 1,200 m 3937.008 ft
Specified cable (twist pair cable with shield)
(Note) Use the CC-Link-specified cable.
1 to 64 (0 and 65 or more: Error)
Remote device station
-10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45 degrees +14 to +113 degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Heat-resistant ABS
Connector cap: Silicone rubber
Net weight: 60 g approx.
Gross weight: 100 g approx.
Connector cap: 2 pcs.
12 to 24 V DC +10-15 % Ripple P-P 10 % or less (By power supplied from the SC-GU2-C)
10 mA or less
Enclosure: Heat-resistant ABS
Net weight: 20 g approx.
Gross weight: 40 g approx.
-
(Not occupy the signal channel No.)
Green LED (lights up when the power is ON)
0.38 mm2 single shielded cable [Heat resistant PVC (Black)]
dia. 1.46 mm dia. 0.057 in
30 to 180 mm 1.181 to 7.087 in adjustable by cable length adjust button
Main body side: 20 N
(Note) For length adjustment of cable with communication connector, pull out the cable slowly. To remove the cable with communication connector from SC-GU2-C, hold the connector and remove it.