Specification

Specifications table for model SC-MIL
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Supply Voltage 12 to 24 V DC plus or minus 10 % (In combination with SC-TP8J, the unit can be also used with a power supply of 5 to 24 V DC plus or minus 10 %.)
(Note:The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply.)
Allowable Passing Current2 A or less (Same as maximum permissible current consumption of all units connected toSC-MIL-S.)
(Note:When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value. .)
Signal Channel No.Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL-S) of all units connected to SC-MIL-S is transferred. However, the signal thereafter is not transferred. Note that SC-MIL-S does not occupy any signal point.)
Max. Distance Between Units10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
Ambient Temperature–10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed),
Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
MaterialEnclosure: Heat-resistant ABS
Weight (Typ.)Net weight: 25 g approx.
AccessoryConnector protection seal: 1 pc.

Stock Check