Specification

Specifications table for model FX-CH2
ItemPerformance characteristics
Applicable SensorsFX-301(P) (Note) , FX-305(P)
(Note) Only updated version of FX-301(P) can be used. Do not use the previous version of FX-301(P). The updated version of FX-301(P) have ''NAVI'' printed on one side.
Supply Voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Power Consumption600 mW or less (when all indicators light up)
InputLow: 0 to +2 V DC
Source current 0.5 mA
Input impedance 10 kOhm approx.
High: +5 V to +V DC, or open
Power Indicator Green LED (Lights up when the power is ON)
Transmission Operation IndicatorGreen LED (Lights up when loaded, and 2-level / Limit teaching, blinks to lights up when saved, and Full-auto teaching)
Ambient Temperature-10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 sensors are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 sensors are connected in cascade: -10 to +45 degrees +14 to +113 degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
MaterialEnclosure: Heat-resistant ABS
Connecting MethodConnector
(Note) The cable for unit connection is not supplied as an accessory. Be sure to use the optional quick-connection cables given below.
Main cable (3-core)
CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
AccessoryCN-EP1 (Connector for input device) (Note) : 1 pc.
(Note) The applicable wire is 0.08 mm2 (AWG 28) to 0.5 mm2 (AWG 20) and the wire sheath diameter should be dia. 1.5 mm dia. 0.059 in or less.
Weight (Typ.)Net weight: 20 g approx.
Gross weight: 40 g approx.