FZ-10 Color Detection Fiber Sensors are equipped with three LEDs - red, green and blue - as their light source. This contributes to a long Sensor life and a high immunity against disturbances through ambient light. The RGB components of each detected color are processed digitally, thus the smallest differences will be detected by this Sensor. Even white and yellow can be distinguished.
By pressing just a single button, the Sensor memorizes the inspected color as a reference. Allowable deviations from this target color can be set with a 16-step tolerance adjuster. Four different fibers with spot diameters from 1 to 8mm and different sensing ranges are available for this Color Sensor. With a response time of only 1ms, FZ-10 Color Detection Sensors are also suitable for high-speed color-checking applications.
Characteristics:
Excellent Color Detection
"Teach-In" Button For Easy Sensor Adjustment
16-Step Tolerance Adjuster
Response Time Only 1ms
Miniature Construction
High Ambient Light Immunity
Long Life
Timer Function
Color Detection Fiber Sensor FZ-10
Part number list
Results 6
Models table for series Color Detection Fiber Sensor FZ-10
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
45 mA or less
Opaque or translucent object larger than the spot diameter of the applicable fiber (Note) Make sure to confirm detection with an actual sensor before use.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Coincident-ON or Incoincident-ON
Incorporated
1 ms or less (3 ms or less when auto-teaching has been engaged)
Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching) Operation indicator: Red LED (lights up when the output is ON) * Both blink alternately when a manual teaching error occurs Both blink simultaneously when the output is short-circuited
Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective)
Button operation, Switchable either manual-teaching or auto-teaching
Adjustable in 16 grades with the tolerance adjuster
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) , Storage: -20 to +70 ℃ -4 to +158 ℉ (Note) The amplifier should be used under the ambient temperature of +15 to +35 ℃ +59 to +95 ℉ when the tolerance adjuster is set from the 1st grade to the 4th grade, which provide fine color resolution.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil, modulated)
Enclosure: ABS Case cover: Polycarbonate Fiber lock lever: PPS
0.2 mm2 3-core cabtyre cable, 2 m 328.084 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
45 mA or less
Opaque or translucent object larger than the spot diameter of the applicable fiber (Note) Make sure to confirm detection with an actual sensor before use.
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
Switchable either Coincident-ON or Incoincident-ON
Incorporated
1 ms or less (3 ms or less when auto-teaching has been engaged)
Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching) Operation indicator: Red LED (lights up when the output is ON) * Both blink alternately when a manual teaching error occurs Both blink simultaneously when the output is short-circuited
Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective)
Button operation, Switchable either manual-teaching or auto-teaching
Adjustable in 16 grades with the tolerance adjuster
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) , Storage: -20 to +70 ℃ -4 to +158 ℉ (Note) The amplifier should be used under the ambient temperature of +15 to +35 ℃ +59 to +95 ℉ when the tolerance adjuster is set from the 1st grade to the 4th grade, which provide fine color resolution.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil, modulated)
Enclosure: ABS Case cover: Polycarbonate Fiber lock lever: PPS
0.2 mm2 3-core cabtyre cable, 2 m 328.084 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
8 to 11 mm 0.315 to 0.433 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
10 mm 0.394 in(fixed)
dia. 2.5 mm dia. 0.098 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
30 to 50 mm 0.181 to 1.969 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
40 mm 1.575 in(fixed)
dia. 8 mm dia. 0.315 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
4 to 6 mm 0.157 to 0.236 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
5 mm 0.197 in(fixed)
dia. 1 mm dia. 0.039 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
14 to 24 mm 0.511 to 0.945 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
20 mm 0.787 in(fixed)
dia. 5 mm dia. 0.197 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
1 m 3.281 ft
Models table for series Color Detection Fiber Sensor FZ-10
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
45 mA or less
Opaque or translucent object larger than the spot diameter of the applicable fiber (Note) Make sure to confirm detection with an actual sensor before use.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Coincident-ON or Incoincident-ON
Incorporated
1 ms or less (3 ms or less when auto-teaching has been engaged)
Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching) Operation indicator: Red LED (lights up when the output is ON) * Both blink alternately when a manual teaching error occurs Both blink simultaneously when the output is short-circuited
Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective)
Button operation, Switchable either manual-teaching or auto-teaching
Adjustable in 16 grades with the tolerance adjuster
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) , Storage: -20 to +70 ℃ -4 to +158 ℉ (Note) The amplifier should be used under the ambient temperature of +15 to +35 ℃ +59 to +95 ℉ when the tolerance adjuster is set from the 1st grade to the 4th grade, which provide fine color resolution.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil, modulated)
Enclosure: ABS Case cover: Polycarbonate Fiber lock lever: PPS
0.2 mm2 3-core cabtyre cable, 2 m 328.084 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
45 mA or less
Opaque or translucent object larger than the spot diameter of the applicable fiber (Note) Make sure to confirm detection with an actual sensor before use.
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
Switchable either Coincident-ON or Incoincident-ON
Incorporated
1 ms or less (3 ms or less when auto-teaching has been engaged)
Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching) Operation indicator: Red LED (lights up when the output is ON) * Both blink alternately when a manual teaching error occurs Both blink simultaneously when the output is short-circuited
Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective)
Button operation, Switchable either manual-teaching or auto-teaching
Adjustable in 16 grades with the tolerance adjuster
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) , Storage: -20 to +70 ℃ -4 to +158 ℉ (Note) The amplifier should be used under the ambient temperature of +15 to +35 ℃ +59 to +95 ℉ when the tolerance adjuster is set from the 1st grade to the 4th grade, which provide fine color resolution.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil, modulated)
Enclosure: ABS Case cover: Polycarbonate Fiber lock lever: PPS
0.2 mm2 3-core cabtyre cable, 2 m 328.084 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
8 to 11 mm 0.315 to 0.433 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
10 mm 0.394 in(fixed)
dia. 2.5 mm dia. 0.098 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
30 to 50 mm 0.181 to 1.969 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
40 mm 1.575 in(fixed)
dia. 8 mm dia. 0.315 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
4 to 6 mm 0.157 to 0.236 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
5 mm 0.197 in(fixed)
dia. 1 mm dia. 0.039 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
14 to 24 mm 0.511 to 0.945 in (Note) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade of tolerance.
20 mm 0.787 in(fixed)
dia. 5 mm dia. 0.197 in
R25 mm R0.984 in or more (Note) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.