Compact & Low Price Inductive Proximity Sensor GL

Compact and low-cost Inductive Proximity Sensor with built-in amplifier. This Sensor offers high performance in a small body.

Part Number List

Results 6
Models table for series Compact & Low Price Inductive Proximity Sensor GL
Part No.DatasheetCE Marking Directive ComplianceMax. Operation DistanceStable Sensing RangeStandard Sensing Object HysteresisSupply Voltage Current ConsumptionOutputOutput: Utilization Category Output: Output Operation Max. Response FrequencyOperation Indicator Environmental Resistance: Pollution DegreeProtectionAmbient TemperatureAmbient HumidityVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceSensing Range Variation: Temperature Characteristics Sensing Range Variation: Voltage Characteristics MaterialCableCable ExtensionWeight (Typ.)Accessories
EMC Directive, RoHS Directive
5 mm 0.197 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 4 mm 0 to 0.157 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally open
1kHz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
-
EMC Directive, RoHS Directive
12 mm 0.472 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 10 mm 0 to 0.394 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally closed
500Hz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
MS-GL18HL (Sensor mounting bracket): 1 set
EMC Directive, RoHS Directive
5 mm 0.197 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 4 mm 0 to 0.157 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally closed
1kHz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
-
EMC Directive, RoHS Directive
5 mm 0.197 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 4 mm 0 to 0.157 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally open
1kHz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
-
EMC Directive, RoHS Directive
12 mm 0.472 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 10 mm 0 to 0.394 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally open
500Hz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
MS-GL18HL (Sensor mounting bracket): 1 set
EMC Directive, RoHS Directive
12 mm 0.472 in ± 10 %
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 10 mm 0 to 0.394 in
(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
10 to 30 V DC Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Normally open
500Hz
Red LED (lights up when the output is ON)
3 (Industrial environment)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -25 to +70 ℃ -13 to +158℉
45 to 85 % RH, Storage: 45 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within ±10 % of sensing range at +20 ℃ +68℉
Within ±2 % for ±10 % fluctuation of the supply voltage
Enclosure: Polyarylate
0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 45 g approx.
MS-GL18HL (Sensor mounting bracket): 1 set