Housed in a lightweight but strong die-cast aluminum case, the compact HG-C Series pairs a highly precise CMOS Image Sensor with a newly designed optical system to achieve a more compact form factor while maintaining highly accurate and precise measurements in the order of 1/100 mm (0.0003 In.).
Characteristics:
Incredibly stable and accurate measurements
Compact and lightweight form factor
Variety of useful functions and features
IO Link version available (link to HG-CL1000 series)
CMOS type Micro Laser Distance Sensor HG-C
Part number list
Results 10
Models table for series CMOS type Micro Laser Distance Sensor HG-C
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Models table for series CMOS type Micro Laser Distance Sensor HG-C
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85% RH, Storage: 35 to 85% RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃
Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less
40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less
Either Light-ON or Dark-ON
Incorporated (Auto reset type)
• Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω
• Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016.
Switchable between 1.5 ms / 5 ms / 10 ms
PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx.
2
2,000 m 6561.680 ft or less
IP67 (IEC)
-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
5-core composite cable, 2 m 6.5617 ft long
Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Enclosure: Aluminum die-cast Front cover: Acrylic
Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017.
Incredibly Stable and Accurate Measurements
Thanks to a precise and specially designed CMOS image sensor, the HG-C can provide reliable and accurate measurements with a repeatability as small as 10 μm.
Compact and Lightweight Form Factor
The HG-C incorporates a built-in mirror to reduce the physical depth of the sensor while maintaining high accuracy measurements. The solid, die-cast aluminum body provides excellent environmental resistances, IP67-rated protection, and reduces the impact of both strain and heat on the measurement accuracy.
Variety of Useful Functions and Features
The HG-C hosts a variety of configurable functions and features that make it a flexible option for many kinds of applications.
Teaching and window comparator modes
Timer delay function
External input function
Peak and bottom hold function
Analog output (0-5V or 4-20 mA output)
IO-Link Version Available (HG-C1000L)
The HG-C1000L lineup features IO-Link compatibility for enhanced monitoring, data collection, and operation by a host controller (such as a PLC) through an IO-Link master