| | EMC Directive Compliance, FDA Standard | 100mm 3.937 in | ±35mm 1.328 in | 70 μm 2.756 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 200 mm 7.874 in | ±80 mm 3.150 in | 200 μm 7.874 mil | ±0.2%F.S. | 0.03% F.S./℃ | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 30mm 1.181 in | ±5mm 0.197 in | 10 μm 0.394 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 400 mm 15.748 in | ±200 mm 7.874 in | 300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | ±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | 0.03% F.S./℃ | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 100mm 3.937 in | ±35mm 1.328 in | 70 μm 2.756 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø120 μm 4.7241 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 200 mm 7.874 in | ±80 mm 3.150 in | 200 μm 7.874 mil | ±0.2%F.S. | 0.03% F.S./℃ | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (Between control output to 0V) - Residual voltage: 1.5 V or less (At 50 mA sink current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2 V DC - Input impedance: 10 kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 400 mm 15.748 in | ±200 mm 7.874 in | 300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | ±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | 0.03% F.S./℃ | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø500 μm 19.6851 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 50mm 1.969 in | ±15mm 0.591 in | 30 μm 1.181 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 30mm 1.181 in | ±5mm 0.197 in | 10 μm 0.394 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø50 μm 1.969 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | PNP open-collector transistor - Maximum source current: 50mA - Applied voltage: 30V DC or less (Between control output to +V) - Residual voltage: 1.5V or less (At 50mA source current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | PNP non-contact input - Input conditions Invalid: 0 to +0.6V DC or Open Valid: +4 to +V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
| | EMC Directive Compliance, FDA Standard | 50mm 1.969 in | ±15mm 0.591 in | 30 μm 1.181 mil | ±0.1%F.S. | 0.03% F.S. /℃ | Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note) Max. output: 1mW emission peak wavelength: 655nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). | ø70 μm 1.1811 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. | 12 to 24V DCplus or minus 10% Ripple P-P 10% | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) | NPN open-collector transistor - Maximum sink current: 50mA - Applied voltage: 30V DC or less (Between control output to 0V) - Residual voltage: 1.5V or less (At 50mA sink current) - Leakage current: 0.1 mA or less | Either Light-ON or Dark-ON | Incorporated (Auto reset type) | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. | Switchable between 1.5 ms / 5 ms / 10 ms | NPN non-contact input - Input conditions Invalid: +8 to +V DC or Open Valid: 0 to +1.2V DC - Input impedance: 10kΩ approx. | 2 | 2,000 m 6561.680 ft or less | IP67 (IEC) | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ | 35 to 85% RH, Storage: 35 to 85% RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | 5-core composite cable, 2 m 6.5617 ft long | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast Front cover: Acrylic | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |