Item | Performance characteristics |
---|---|
Regulatory Compliance and Certification | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification |
Measurement Center Distance | 400 mm 15.748 in |
Measuring Range | ±200 mm 7.874 in |
Repeatability | 300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in) |
Linearity | ±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in) |
Temperature Characteristics | 0.03%F.S./℃ |
Light Source | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). |
Beam Diameter | ø500 μm 19.685 mil approx. |
Supply Voltage | 24 V DC ±10 % Ripple P-P 10 % |
Current Consumption | 40 mA or less (at 24 V DC supply voltage) |
Communication Output (C/Q): IO-Link Communication | IO-Link Specification V1.1 |
Communication Output (C/Q): Baud Rate | COM3 (230.4 kbps) |
Communication Output (C/Q): Process Data | 4 byte |
Communication Output (C/Q) : Minimum Cycle Time | 1.0 ms |
Control Output | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less |
Control Output: Output Operation | Switchable between either Light-ON or Dark-ON |
Control Output: Short-Circuit Protection | Incorporated (auto reset type) |
Response Time | Switchable between 1.5 ms / 5 ms / 10 ms |
Pollution Degree | 2 |
Operating Altitude | 2,000 m 6561.680 ft or less |
Protection | IP67(IEC) |
Ambient Temperature | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
Vibration Resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Cable | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long |
Cable Extension | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. |
Material | Enclosure: Aluminum die-cast, Front cover: Acrylic |
Weight (Typ.) | 30 g approx. (without cable), 80 g approx. (including cable) |
Remark | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |