| | EMC Directive, RoHS Directive | 30 to 200 mm 1.181 to 7.874 in (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. | dia. 15 mm dia. 0.591 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 30 to 200 mm 1.181 to 7.874 in (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. | dia. 15 mm dia. 0.591 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 30 to 200 mm 1.181 to 7.874 in (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. | dia. 15 mm dia. 0.591 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 30 to 200 mm 1.181 to 7.874 in (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. | dia. 15 mm dia. 0.591 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 45 to 115 mm 1.772 to 4.528 in with white non-glossy paper (100 x 100 mm 3.937 x 3.937 in), spot diameter dia. 5 mm dia. 0.197 in with setting distance 80 mm 3.150 in | Opaque, translucent or transparent object (Note) (Min. dia. 1 mm dia. 0.039 in copper wire at setting distance 80 mm 3.150 in) (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance [100 x 100 mm 3.937 x 3.937 in with white non-glossy paper] | 0.3 mm 0.012 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 650 nm 0.026 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc. |
| | EMC Directive, RoHS Directive | 45 to 115 mm 1.772 to 4.528 in with white non-glossy paper (100 x 100 mm 3.937 x 3.937 in), spot diameter dia. 5 mm dia. 0.197 in with setting distance 80 mm 3.150 in | Opaque, translucent or transparent object (Note) (Min. dia. 1 mm dia. 0.039 in copper wire at setting distance 80 mm 3.150 in) (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance [100 x 100 mm 3.937 x 3.937 in with white non-glossy paper] | 0.3 mm 0.012 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 650 nm 0.026 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc. |
| | EMC Directive, RoHS Directive | 45 to 115 mm 1.772 to 4.528 in with white non-glossy paper (100 x 100 mm 3.937 x 3.937 in), spot diameter dia. 5 mm dia. 0.197 in with setting distance 80 mm 3.150 in | Opaque, translucent or transparent object (Note) (Min. dia. 1 mm dia. 0.039 in copper wire at setting distance 80 mm 3.150 in) (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance [100 x 100 mm 3.937 x 3.937 in with white non-glossy paper] | 0.3 mm 0.012 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 650 nm 0.026 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | Adjusting screwdriver: 1 pc. |
| | EMC Directive, RoHS Directive | 30 to 200 mm 1.181 to 7.874 in (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. | dia. 15 mm dia. 0.591 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-200 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 30 mm 1.181 in away. However, if the reflector is set 100 mm 3.937 in or less away, the sensing object should be opaque. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | RF-200 (Reflector): 1 pc Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 5 to 160 mm 0.197 to 6.299 in (Note) with white non-glossy paper (200 x 200 mm) (7.874 x 7.874 in) (Note) In case of using this product at a sensing range of 50 mm 1.969 in or less, take care that the sensitivity adjustment range becomes extremely narrow. | Opaque,translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance [200 x 200 mm 7.874 x 7.874 in with white non-glossy paper] | 0.3 mm 0.012 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc |
| | EMC Directive, RoHS Directive | 5 to 160 mm 0.197 to 6.299 in (Note) with white non-glossy paper (200 x 200 mm) (7.874 x 7.874 in) (Note) In case of using this product at a sensing range of 50 mm 1.969 in or less, take care that the sensitivity adjustment range becomes extremely narrow. | Opaque,translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance [200 x 200 mm 7.874 x 7.874 in with white non-glossy paper] | 0.3 mm 0.012 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 13 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | DC-12 or DC-13 | Incorporated | 0.5 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | IP67 (IEC) | - | Continuously variable adjuster | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 680 nm 0.027 mil | Enclosure: Polyethylene terephthalate Lens: Polyalylate | 0.1 mm2 3-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 20 g approx Gross weight: 45 g approx | Adjusting screwdriver: 1 pc |