| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.2 to 2.5 m 0.656 to 8.202 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 2.5 m 0.328 to 8.202 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 24-240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less | AC: 5 VA or less DC: 4 W or less | Relay contact 1a - Switching capacity: 2 50 V AC 3 A (resistive load), 30 V DC 3 A (resistive load) - Electrical life: 100,000 or more switching operations (switching frequency 1,200 operations/hour) - Mechanical life: 50 million or more switching operations (switching frequency 18,000 operations/hour) | Switchable either Detection-ON or Detection-OFF | - | 20 ms or less (depends on the setting timer period) | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | - | Incorporated with variable (0.1 to 5 sec.) ON-delay/OFF-delay timer | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 2,000 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 100 MOhm , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 100 g approx. | Adjusting screwdriver: 1 pc. | 10 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | AC-12/DC-12 | 2.5 kV | DC 5 V 1 mA or more | 20 ms / 20 ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 25 Hz Note : The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | 3 (Industrial environment) | Out of classification | 12 % Note : Excess gain is the value in case the distance setting adjuster is positined in maximum state. In addition, sensing object 200mm x 200mm is the value in case of non-glossy white paper. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.In addition, use 5A or less fast blow fuse or breaker. |
| | ・EMC Directive : EN 60947-5-2 ・RoHS Directive | 0.2 to 2.5 m 0.656 to 8.202 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 2.5 m 0.328 to 8.202 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 45 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | Switchable either Detection-ON or Detection-OFF | Incorporated | 2 ms or less (depends on the setting timer period) | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | Switchable either BGS or FGS function | Incorporated with variable (0.1 to 5 sec.) ON-delay/OFF-delay timer | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 85 g approx. | Adjusting screwdriver: 1 pc. | 10 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | | | | | | | | | |
| | ・EMC Directive : EN 60947-5-2 ・RoHS Directive | 0.2 to 2.5 m 0.656 to 8.202 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 2.5 m 0.328 to 8.202 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 45 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | Switchable either Detection-ON or Detection-OFF | Incorporated | 2 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | Switchable either BGS or FGS function | - | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 85 g approx. | Adjusting screwdriver: 1 pc. | 10 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | | | | | | | | | |
| | ・EMC Directive : EN 60947-5-2 ・RoHS Directive | 0.2 to 1.0 m 0.656 to 3.281 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 1.0 m 0.328 to 3.281 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 45 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | Switchable either Detection-ON or Detection-OFF | Incorporated | 2 ms or less (depends on the setting timer period) | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | Switchable either BGS or FGS function | Incorporated with variable (0.1 to 5 sec.) ON-delay/OFF-delay timer | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 85 g approx. | Adjusting screwdriver: 1 pc. | 4 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | | | | | | | | | |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.2 to 2.5 m 0.656 to 8.202 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 2.5 m 0.328 to 8.202 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 24-240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less | AC: 4 VA or less DC: 3 W or less | Relay contact 1a - Switching capacity: 2 50 V AC 3 A (resistive load), 30 V DC 3 A (resistive load) - Electrical life: 100,000 or more switching operations (switching frequency 1,200 operations/hour) - Mechanical life: 50 million or more switching operations (switching frequency 18,000 operations/hour) | Switchable either Detection-ON or Detection-OFF | - | 20 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | - | - | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 2,000 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 100 MOhm , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 100 g approx. | Adjusting screwdriver: 1 pc. | 10 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | AC-12/DC-12 | 2.5 kV | DC 5 V 1 mA or more | 20 ms / 20 ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 25 Hz Note : The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | 3 (Industrial environment) | Out of classification | 12 % Note : Excess gain is the value in case the distance setting adjuster is positined in maximum state. In addition, sensing object 200mm x 200mm is the value in case of non-glossy white paper. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.In addition, use 5A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.2 to 1.0 m 0.656 to 3.281 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 1.0 m 0.328 to 3.281 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 24-240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less | AC: 5 VA or less DC: 4 W or less | Relay contact 1a - Switching capacity: 2 50 V AC 3 A (resistive load), 30 V DC 3 A (resistive load) - Electrical life: 100,000 or more switching operations (switching frequency 1,200 operations/hour) - Mechanical life: 50 million or more switching operations (switching frequency 18,000 operations/hour) | Switchable either Detection-ON or Detection-OFF | - | 20 ms or less (depends on the setting timer period) | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | - | Incorporated with variable (0.1 to 5 sec.) ON-delay/OFF-delay timer | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 2,000 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 100 MOhm , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 100 g approx. | Adjusting screwdriver: 1 pc. | 4 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | AC-12/DC-12 | 2.5 kV | DC 5 V 1 mA or more | 20 ms / 20 ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 25 Hz Note : The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | 3 (Industrial environment) | Out of classification | 12 % Note : Excess gain is the value in case the distance setting adjuster is positined in maximum state. In addition, sensing object 200mm x 200mm is the value in case of non-glossy white paper. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.In addition, use 5A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.2 to 1.0 m 0.656 to 3.281 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 1.0 m 0.328 to 3.281 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 24-240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less | AC: 4 VA or less DC: 3 W or less | Relay contact 1a - Switching capacity: 2 50 V AC 3 A (resistive load), 30 V DC 3 A (resistive load) - Electrical life: 100,000 or more switching operations (switching frequency 1,200 operations/hour) - Mechanical life: 50 million or more switching operations (switching frequency 18,000 operations/hour) | Switchable either Detection-ON or Detection-OFF | - | 20 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | - | - | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 2,000 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 100 MOhm , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 100 g approx. | Adjusting screwdriver: 1 pc. | 4 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | AC-12/DC-12 | 2.5 kV | DC 5 V 1 mA or more | 20 ms / 20 ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 25 Hz Note : The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | 3 (Industrial environment) | Out of classification | 12 % Note : Excess gain is the value in case the distance setting adjuster is positined in maximum state. In addition, sensing object 200mm x 200mm is the value in case of non-glossy white paper. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.In addition, use 5A or less fast blow fuse or breaker. |
| | ・EMC Directive : EN 60947-5-2 ・RoHS Directive | 0.2 to 1.0 m 0.656 to 3.281 ft (Note 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m 0.328 ft, or more, away. (Note 2) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.1 to 1.0 m 0.328 to 3.281 ft (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 10 % or less of operation distance (Note) The adjustable range, sensing range and hysteresis are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 45 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | Switchable either Detection-ON or Detection-OFF | Incorporated | 2 ms or less | Orange LED (lights up when the output is ON) | Green LED (lights up under stable operating condition) | 2-turn mechanical adjuster with indicator | Switchable either BGS or FGS function | - | Incorporated (Note) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. | IP67 (IEC) | –25 to +55 ℃ –13 to +131 ℉ (No dew condensation or icing allowed), Storage: –30 to +70 ℃ –22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated) | 2-segment photodiode | Enclosure: ABS Front cover: Polycarbonate Display cover: Polycarbonate | Screw-on terminal connection | Suitable for round cable φ9 to φ11 mm φ0.354 to φ0.433 in | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable. | Net weight: 85 g approx. | Adjusting screwdriver: 1 pc. | 4 mm Note : The adjustable range, sensing range, hysteresis and repeatability are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | | | | | | | | | |