Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Sensing Range | 10 m 32.808 ft |
Sensing Object | dia. 10 mm dia. 0.394 in or more opaque object (Note) If slit masks (optional) are fitted, an object of 0.5 x 5 mm 0.020 x 0.197 in can be detected. |
Hysteresis | - |
Repeatability (Perpendicular to Sensing Axis) | 0.5 mm 0.020 in or less |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | Emitter: 20 mA or less Receiver: 25 mA or less |
Sensing Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
Sensing Output: Utilization Category | DC-12 or DC-13 |
Sensing Output: Output Operation | Switchable either Light-ON or Dark-ON |
Sensing Output: Short-Circuit Protection | Incorporated |
Self-Diagnosis Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
Self-Diagnosis Output: Output Operation | ON under unstable sensing condition |
Self-Diagnosis Output: Short-Circuit Protection | - |
Response Time | 1 ms or less |
Test Input (Emission Halt) Function | Incorporated |
Stability Indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Operation Indicator | Red LED (lights up when the sensing output is ON) |
Emitting Indicator | Red LED (lights up during beam emission) |
Automatic Interference Prevention Function | - |
Sensitivity Adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient Temperature | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting Element (Modulated) | Infrared LED |
Emitting Element (Modulated): Peak Emission Wavelength | 880 nm 0.035 mil |
Material | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate |
Cable | Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). |
Weight (Typ.) | Emitter: 70 g approx Receiver: 70 g approx |
Accessory | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.