Specification

Specifications table for model RX-PRVM3
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Sensing Range 0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
Sensing Object dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
Hysteresis-
Repeatability (Perpendicular to Sensing Axis) 1 mm 0.039 in or less
Supply Voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current Consumption40 mA or less
Sensing Output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Sensing Output: Utilization CategoryDC-12 or DC-13
Sensing Output: Output OperationSwitchable either Light-ON or Dark-ON
Sensing Output: Short-Circuit ProtectionIncorporated
Self-Diagnosis OutputNPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Self-Diagnosis Output: Output OperationON under unstable sensing condition
Self-Diagnosis Output: Short-Circuit Protection-
Response Time1 ms or less
Test Input (Emission Halt) FunctionIncorporated
Stability IndicatorGreen LED (lights up under stable light received condition or stable dark condition)
Operation Indicator Red LED (lights up when the sensing output is ON)
Emitting Indicator-
Automatic Interference Prevention FunctionIncorporated (Two units of sensors can be mounted close together.)
Sensitivity AdjusterContinuously variable adjuster
ProtectionIP67 (IEC)
Ambient Temperature-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient IlluminanceIncandescent light: 3,500 Lx or less at the light-receiving face
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock Resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Emitting Element (Modulated)Red LED
Emitting Element (Modulated): Peak Emission Wavelength680 nm 0.027 mil
MaterialEnclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Acrylic
Cable0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Cable ExtensionExtension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Weight (Typ.)75 g approx.
AccessoryMS-RX-1 (Sensor mounting bracket): 1 set
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.