| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.3 mm 0.012 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Dark-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 140 g approx. | Adjusting screwdriver: 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 14% Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.3 mm 0.012 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Dark-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | | Adjusting screwdriver: 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 14% Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 10 m 32.808 ft | dia. 20 mm dia. 0.787 in or more opaque object (Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. | - | 0.1 mm 0.004 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | Emitter: 1 VA or less Receiver: 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Light-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | (Use optional interference prevention filters) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 660 nm 0.026 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | Emitter: 100 g approx Receiver: 140 g approx | Adjusting screwdriver: 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 30% Note : Excess gain of NX5-M10□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. | dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.2 mm 0.008 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Dark-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 660 nm 0.026 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate Front cover: Acylic | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 140 g approx. | RF-230 (Reflector): 1 pc Adjusting screwdriver: 1 pc | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 10% Note : Excess gain of NX5-PRVM5□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. | dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.2 mm 0.008 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Dark-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Red LED (modulated) | 660 nm 0.026 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate Front cover: Acylic | 0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | | RF-230 (Reflector): 1 pc Adjusting screwdriver: 1 pc | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 10% Note : Excess gain of NX5-PRVM5□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.3 mm 0.012 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Light-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 140 g approx. | Adjusting screwdriver: 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 14% Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.3 mm 0.012 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Light-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | Continuously variable adjuster | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | | Adjusting screwdriver: 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 14% Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position. | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 30 m 98.425 ft | dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object) (Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. | - | 0.2 mm 0.008 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | Emitter: 1.5 VA or less Receiver: 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Light-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the power is ON) | - | - | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | Emitter: 125 g approx Receiver: 140 g approx | - | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 30% | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 30 m 98.425 ft | dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object) (Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. | - | 0.2 mm 0.008 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | Emitter: 1.5 VA or less Receiver: 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Light-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the power is ON) | - | - | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate | 0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | | - | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 30% | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
| | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 | 0.1 to 7 m 0.328 to 22.966 ft (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. | dia. 50 mm dia. 1.969 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. | - | 0.2 mm 0.008 in or less | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less | 2 VA or less | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) | Dark-ON | 10 ms or less | Red LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | - | - | Incorporated (Two units of sensors can be mounted close together.) | 3 (Industrial environment) | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. | IP66 (IEC) | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | Infrared LED (modulated) | 880 nm 0.035 mil | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate Front cover: Acylic | 0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | | RF-230 (Reflector): 1 pc. | AC-12/DC-12 | 2.5kV | DC5V 1mA or more | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) | Out of classification | 10% | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |