Specifications
Item | Performance characteristics |
---|---|
Applicable Amplifiers | SU-7 series |
Sensing Range | 100 mm 3.937 in |
Sensing Object | Min. ø1 mm ø0.039 in opaque object (with 100 mm 3.937 in setting distance and at the optimum sensitivity) Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition. |
Hysteresis | - |
Repeatability (Perpendicular to Sensing Axis) | 0.1 mm 0.004 in or less |
Operation Indicator | Red LED(lights up when the sensing output of the amplifier is ON, incorporated on the emitter of the thru-beam type sensor head) |
Protection | IP66 (IEC) |
Ambient Temperature | -25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed) Storage: -30 to +70 ℃ -22 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 lx or less at the light-receiving face |
Vibration Resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting Element | Green LED(modulated) |
Emitting Element: Peak Emission Wavelength | 570 nm 0.022 mil |
Material | Enclosure: ABS, Lens: Polycarbonate |
Cable | 0.089 mm2 single core shielded cable, 3 m 9.843 ft long |
Cable Extension | Extension up to total 10 m 32.808 ft is possible with an equivalent cable (thru-beam type: both emitter and receiver). |
Weight (Typ.) | Emitter: 10 g approx. Receiver: 10 g approx. |
Accessory | - |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |