Specification

Specifications table for model SU-7
ItemPerformance characteristics
Applicable Sensor HeadSH series
Supply Voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current Consumption35 mA or less
Sensing Output
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between sensing output and 0 V)
・Residual voltage: 1.0 V or less (at 100 mA sink current)
        0.4 V or less (at 16 mA sink current)
Sensing Output: Output OperationSelectable either Light-ON or Dark-ON with the ON and OFF buttons
Sensing Output: Short-Circuit ProtectionIncorporated
Self-Diagnosis Output
NPN open-collector transistor
・Maximum sink current: 50 mA
・Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
・Residual voltage: 1.0 V or less (at 50 mA sink current)
        0.4 V or less (at 16 mA sink current)
Self-Diagnosis Output: Output OperationON under unstable sensing condition (restored automatically after 40 ms approx.), or if the sensing output is short-circuited (restored when short-circuit is rectified).
(For the remote sensitivity adjustment type, it turns ON for 40 ms approx. Also after the remote sensitivity input is received.)
Self-Diagnosis Output: Short-Circuit Protection-
Response Time0.6 ms or less (0.8 ms or less when the interference prevention function is used)
Operation Indicator Red LED (lights up when the sensing output is ON)
Stability IndicatorGreen LED
("RUN" mode: Lights up under stable light received condition or stable dark condition
"SET" mode: At the time of sensitivity setting, blinks twice when the difference between ON and OFF levels is greater than the hysteresis, but blinks 15 times when it is equal to or less than the hysteresis. Also blinks twice after the interference prevention is set
"SET" mode → When "SIF" or "RUN" mode is selected: Blinks from 0 to 5 times according to the sensitivity margin)
Test Input (Emission Halt) Function-
External Synchronization Function-
Remote Sensitivity Setting Function -
Remote Sensitivity Selection Function-
Sensitivity Shift & Limit Sensitivity Setting FunctionsShifts the set sensitivity level
Automatic Interference Prevention FunctionIncorporated
Timer Function ON-delay / OFF-delay timer (variable 0 to 5 sec.)
Ambient Temperature-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
MaterialEnclosure: Heat-resistant ABS, Case cover: Polycarbonate, Cable lock lever: PPS
Cable0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Cable ExtensionExtension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Weight (Typ.)Net weight: 65 g approx.
AccessoryMS-DIN-2 (Amplifier mounting bracket): 1 pc., SU-CT1 (Stripper): 1 pc.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.