Specifications
Item | Performance characteristics |
---|---|
Applicable Sensor Head | SH series |
Supply Voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
Current Consumption | 35 mA or less |
Sensing Output | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between sensing output and 0 V) ・Residual voltage: 1.0 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) |
Sensing Output: Output Operation | Selectable either Light-ON or Dark-ON with the ON and OFF buttons (Selectable with the external inputs for SU-77) |
Sensing Output: Short-Circuit Protection | Incorporated |
Self-Diagnosis Output | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) ・Residual voltage: 1.0 V or less (at 50 mA sink current) 0.4 V or less (at 16 mA sink current) |
Self-Diagnosis Output: Output Operation | ON under unstable sensing condition (restored automatically after 40 ms approx.), or if the sensing output is short-circuited (restored when short-circuit is rectified). (For the remote sensitivity adjustment type, it turns ON for 40 ms approx. Also after the remote sensitivity input is received.) |
Self-Diagnosis Output: Short-Circuit Protection | - |
Response Time | 0.6 ms or less (0.8 ms or less when the interference prevention function is used) |
Operation Indicator | Red LED (lights up when the sensing output is ON) |
Stability Indicator | Green LED ("RUN" mode: Lights up under stable light received condition or stable dark condition "SET" mode: At the time of sensitivity setting, blinks twice when the difference between ON and OFF levels is greater than the hysteresis, but blinks 15 times when it is equal to or less than the hysteresis. Also blinks twice after the interference prevention is set "SET" mode → When "SIF" or "RUN" mode is selected: Blinks from 0 to 5 times according to the sensitivity margin) |
Test Input (Emission Halt) Function | - |
External Synchronization Function | - |
Remote Sensitivity Setting Function | Incorporated |
Remote Sensitivity Selection Function | - |
Sensitivity Shift & Limit Sensitivity Setting Functions | Shifts the set sensitivity level |
Automatic Interference Prevention Function | Incorporated |
Timer Function | ON-delay / OFF-delay timer (variable 0 to 5 sec.) |
Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Cable lock lever: PPS |
Cable | 0.15 mm2 6-core cabtyre cable, 2 m 6.562 ft long |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
Weight (Typ.) | Net weight: 65 g approx. |
Accessory | MS-DIN-2 (Amplifier mounting bracket): 1 pc., SU-CT1 (Stripper): 1 pc. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |