Digital Pressure Sensor [For Gas] DP-0

With the DP-0 Series, Panasonic launches a new digital Pressure Sensor which focuses on very simple operation.  This Pressure Sensor has been developed especially for the electrical and electronic, semiconductor and auto-assembly industry, but can be also used in the biomedical industry (laboratory automation), where simplicity and performance are key objectives.

Compared to the DP-100 series, which features a multitude of functions, the DP-0 Series has been designed to make configuration fast and simple.

 

  • Two Levels of Configuration for Easy Operation
  • Simple And Highly Visible Display
  • Compact and Lightweight Design
  • Two Types Available: Low-pressure type (-100kPa to +100kPa) and High-pressure type (0 To 1MPa) 
IA-DP-0-Band-1

Two Levels of Configuration for Easy Operation

The two-level settings menu allows for quick and simple operation.

•"RUN mode" configures the threshold value,  zero-point adjustment, and key lock/release settings

•"Detailed configuration" configures the sensor's basic operation settings

IA-DP-0-Band-2

Simple and Highly Visible Display

The high-contrast LCD offers excellent visibility and a wide viewing angle so that the display is easy to see even from an oblique angle. 

IA-DP-0-Band-3_350x280

Compact and Lightweight Design

With a measured depth of only 24.9 mm (0.980 in) and a weight of 25 g, the DP-0 can be installed in tight spaces and presents a minimal load when mounted on a moving part such as a robot arm.

IA DP-0 Band 4

Two Types Available: Low-Pressure Type and High-Pressure Type

The DP-0 series offers both a low-pressure type sensor and a high-pressure type sensor to support various applications.  The low-pressure type is suitable for either positive or negative pressure, while the high-pressure type is suitable for positive pressure of up to 1 MPa.

Part Number List

Results 8
Models table for series Digital Pressure Sensor [For Gas] DP-0
Part No.DatasheetCE Marking Directive ComplianceType of Pressure Rated Pressure Range Set Pressure Range Pressure WithstandabilityApplicable FluidSelectable UnitsSupply Voltage Power ConsumptionComparative OutputComparative Output: Output OperationComparative output: HysteresisComparative Output: RepeatabilityComparative Output: Response TimeComparative Output: Short-Circuit ProtectionDisplayDisplay: Displayable Pressure RangeProtectionAmbient TemperatureAmbient HumidityVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistancePollution Degree Overvoltage Category Usable AltitudeTemperature Characteristics (+20℃ Standard) Grounding MethodPressure Port MaterialWeight (Typ.)AccessoriesRemark
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
500 kPa
Air, non-corrosive gas
kPa, kgf/cm2, bar, psi, mmHg
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and +V)
- Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±1 % F.S.
0 to +50℃ 32 to +122℉: Within ±2.5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
500 kPa
Air, non-corrosive gas
kPa, kgf/cm2, bar, psi, mmHg
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±1 % F.S.
0 to +50℃ 32 to +122℉: Within ±2.5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
0.000 to +1.000 Mpa
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
1.5 MPa
Air, non-corrosive gas
MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±2 % F.S.
0 to +50℃ 32 to +122℉: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
0.000 to +1.000 Mpa
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
1.5 MPa
Air, non-corrosive gas
MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and +V)
- Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±2 % F.S.
0 to +50℃ 32 to +122℉: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
500 kPa
Air, non-corrosive gas
kPa, kgf/cm2, bar, psi, mmHg
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and +V)
- Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±1 % F.S.
0 to +50℃ 32 to +122℉: Within ±2.5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
-100.0 to +100.0 kPa
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
500 kPa
Air, non-corrosive gas
kPa, kgf/cm2, bar, psi, mmHg
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to + 1.010 bar
-14.65 to +14.65 psi
-756 to +756 mmHg
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±1 % F.S.
0 to +50℃ 32 to +122℉: Within ±2.5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
0.000 to +1.000 Mpa
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
1.5 MPa
Air, non-corrosive gas
MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and +V)
- Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±2 % F.S.
0 to +50℃ 32 to +122℉: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Gauge pressure
0.000 to +1.000 Mpa
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
1.5 MPa
Air, non-corrosive gas
MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
30 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between comparative output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current)
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
-0.010 to +1.010 MPa
-0.1 to +10.30 kgf/cm2
-0.1 to + 10.10 bar
-0.1 to +146.5 psi
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
2
I
2,000 m 6,562 ft or less
+10 to +40℃ +50 to +104 ℉: Within ±2 % F.S.
0 to +50℃ 32 to +122℉: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced)
LCD display: Acrylic
Pressure port: Brass (nickel plated)
Mounting threaded part: Brass
O-ring: Nitrile rubber (NBR)
Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.