| | EMC Directive, RoHS Directive | HG-SC□ / HG-TC□ | Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit | 24V DC ±10%, including 0.5V ripple (P-P) (Note) : Power is supplied from a connected controller / master controller. | 200 mA or less | CC-Link IE Field | | | 1 Gbps | | | | | | | Remote device station | | 1 to 120 (decimal) (0 and 121 or more: Error) | | 2 | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. | IP40 (IEC) | 10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed) Storage: -20 to +60 ℃ -4 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | | Ethernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable) (Note) : Use CC-Link Partner Association recommended cable. | Net weight: 100 g approx., Gross weight: 150 g approx. | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉. | 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error) (Note) : For the network number setting on this product, convert the network number to hex and set the hex value. | RX/RY:128 points each (128 bits), 16 bytes, RWr/RWw: 64 points each (64 words), 128 bytes | Server function only, data size 1024 bytes | Line, star, (mixing of line and star types is possible), ring | 100 m 328.084 ft | 121 units (1 master station, 120 slave stations) | Maximum 20 | Maximum of 15 units (one master, 14 slaves) per SC‑HG1‑CEF unit | RX/RY:128 points each (128 bits), 16 bytes,
RWr/RWw: 64 points each (64 words), 128 bytes | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ or more, with 250 V DC megger between all supply
terminals connected together and enclosure | HG-SC□ | Line, star, (mixing of line and star types is possible), ring | 2 | Net weight: 100 g approx., Gross weight: 150 g approx. |
| | EMC Directive, RoHS Directive | HG-SC□, HG-TC□ | | 24 V DC ±10 %, Ripple (P-P) 10 % or less (Within specified power supply voltage range) (Note): Power is supplied from a connected master controller. | 40 mA or less | Two-wire half duplex communication | Start-stop synchronization | MODBUS (RTU / ASCII) / MEWTOCOL-COM | 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 115.2 kbps | Complies with EIA RS-485 | 1 to 99 units when MODBUS (RTU/ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used | Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-485 unit | 1 bit / 2 bits | Even / Odd / None | 8 bits (RTU) / 7 bits (ASCII) | | | | | 2 | 2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. | IP40 (IEC) | -10 to +45 ℃ 14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Unit case : Polycarbonate | Communication cable : 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC | | Net weight : 75 g approx., Gross weight : 120 g approx. | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉. | | | | | | | | | | | | | | | |
| | EMC Directive (Note), RoHS Directive (Note): If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]". | HG-SC□ / HG-TC□ | Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit | 24 V DC ±10 %, including ripple 0.5 V (P-P) (Note): Power is supplied from a connected controller / master controller. | 80 mA or less | Switchable CC-Link Ver.1.10 or 2.00 | | | | | | | | | | Remote device station | CC-Link Ver.1.10 : 4 stations, CC-Link Ver.2.00 : Switchable 2 or 4 stations | 1 to 64 (0 and 65 or more : Error) | ・10 Mbps/100 m 328.084 ft ・5 Mbps/160 m 524.934 ft ・2.5 Mbps/400 m 1,312.336 ft ・625 kbps/900 m 2,952.756 ft ・156 kbps/1,200 m 3,937.008 ft | 2 | 2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. | IP40 (IEC) | -10 to +45 ℃ +14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Unit case : Polycarbonate | | Specified cable (shielded twisted cable) (Note): Use only a special-use communication cable that is approved by the CC-Link Partner Association. | Net weight : 80 g approx., Gross weight : 130 g approx. | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉. | | | | | | | | | | | | | | | |