Leak Detection Sensor EX-F70/EX-F60

By taking advantage of the unique effect of "capillarity", this Sensor is able to deliver reliable high-speed detection of small leaks and viscous liquids. The Sensors' slim compact size and built-in amplifier make them ideally suited for confined spaces.
 

You May Also Be Interested In Time of Flight (ToF) Camera Sensors

Instantly Detect Distance With Time of Flight (ToF) Camera Sensors

Panasonic Time of Flight (ToF) Cameras are compact, real-time, sensing cameras based on the ToF principle. Available in indoor and outdoor models, these cameras instantly detect distance between the camera and the targeted object with depth, infrared, and color (RGB) images. The GC1 indoor model produces RGB (640x480), depth map (320x240) (640x480) images. As well, engineers no longer need separate cameras for the depth, IR, and color images with 14/16/36 bit data formats. The HC4W outdoor model has a wide 90° FOV and is used in various applications such as security, autonomous vehicles and robotics.

Part Number List

Results 22
Models table for series Leak Detection Sensor EX-F70/EX-F60
Part No.DatasheetSensing Object Applicable ConnectorSupply Voltage Current ConsumptionOutputOutput: Output Operation Output: Short-Circuit ProtectionResponse TimeInput No.Indicators: NormalIndicators: ErrorIndicators: Output Fault IndicatorNormal IndicatorProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceEmitting ElementMaterialCableCable ExtensionWeight (Typ.)Accessory
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: PFA
0.1 mm2 3-core PFA cabtyre cable, 3 m 9.843 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 60 g approx.
MS-EX-F6-1(PFA mounting bracket): 1 pc.
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: PFA
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 60 g approx.
MS-EX-F6-2(PVC mounting bracket): 1 pc.
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: PFA
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
MS-EX-F6-2(PVC mounting bracket): 1 pc.
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: PFA
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 60 g approx.
MS-EX-F6-1(PFA mounting bracket): 1 pc.
Water, Fluorinertâ„¢
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
10 mA or less(PNP output type: 15 mA or less)
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: Polypropylene
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
MS-EX-F7-1(SUS mounting bracket): 1 pc.
Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor.
Water, Fluorinertâ„¢
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
10 mA or less(PNP output type: 15 mA or less)
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: Polypropylene
0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 25 g approx.
MS-EX-F7-1(SUS mounting bracket): 1 pc.
Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor.
SL-CP1
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
50 mA or less (for the unit itself), 135 mA or less (including the sensor input current when all outputs of sensors are ON)
Relay contact 1a
- Switching capacity: 30 V 1 A DC (resistive load)
- Min. applied load: 10 mV 10 μA DC
- Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.)
- Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.)
The output relay is ON when the input signal from the sensor is ON
Note : Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly.
5 ms or less (excluding the response time of the sensor)
8 Nos.
Green LED x 8 (light up when the sensor is connected to each channel and the connection setting switch is set to ON)
Red LED x 8 (light up when the leak liquid is detected by a sensor connected to each channel or a sensor is mounted improperly)
Orange LED (lights up when the output relay is ON (normal))
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: ABS, Unit mounting base: POM, Terminal part: PBT
0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Extension up to total less than 10 m 32.808 ft is possible, with 0.3 mm2, or more, cable.
Net weight: 85 g approx.
SL-CP1 (Snap male connector): 8 pcs., MS-SL-2 (Unit mounting base): 1 pc.
Water, Fluorinertâ„¢
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
10 mA or less(PNP output type: 15 mA or less)
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: Polypropylene
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
MS-EX-F7-2, MS-EX-F7-3(PVC mounting bracket) : 1 pc.
Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor.
each for two-point-fixing and adhesive-fixing
Water, Fluorinertâ„¢
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
10 mA or less(PNP output type: 15 mA or less)
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: Polypropylene
0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 25 g approx.
MS-EX-F7-2, MS-EX-F7-3(PVC mounting bracket) : 1 pc.
Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor.
each for two-point-fixing and adhesive-fixing
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Incorporated
50 ms or less
Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
Green LED (lights up when the sensor is mounted properly)
IP67 (IEC)
-10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 â„“x or less at the light-receiving face
Infrared LED (non-modulated)
Enclosure: PFA
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
MS-EX-F6-1(PFA mounting bracket): 1 pc.