Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100

Single-Axis Type Digital Pressure Sensor With Optional Dual 3-Color Display

The Sensor head can be tightened with a hexagonal wrench, making installation easy especially in tight spaces. DPH / DHC-100 Pressure Sensors have a fast response time of just 500 µs. The controller automatically recognizes Sensor heads when they are connected, even if their rated pressure ranges are different. The dual display shows current and threshold values simultaneously. All these features reduce labor costs and increased productivity.

The DPH / DPC-100 Series Digital Pressure Sensors include all of the convenient features of its DP-100 Series sibling, e.g. a 3-color display, an analog output, copying function, etc.

Characteristics

  • Fast Scan Time: 500µs
  • Easy, Direct Installation In Narrow Spaces
  • Sensor Heads For Three (3) Different Pressure Ranges: Positive, Vacuum Or Compound Pressure
  • Stainless Steel Pressure Ports In Three (3) Different Shapes
  • Analog Output
  • Current And Threshold Value In One View
  • Automatic Sensor Head Recognition
  • Three Operation Modes: Easy, Hysteresis And Window Comparator Modes
  • Easy Setting
  • ECO Mode To Save Power

Part Number List

Results 4
Models table for series Head-separated Dual Display Digital Pressure Sensor [For Gas] DPH-100 / DPC-100
Part No.DatasheetCE Marking Directive ComplianceType of Pressure Rated Pressure Range Set Pressure Range Supply Voltage Power ConsumptionSensor Head Supply Voltage Comparative OutputComparative Output: Output OperationComparative Output: Output ModesComparative Output: HysteresisComparative Output: RepeatabilityComparative Output: Response TimeComparative Output: Short-Circuit ProtectionAnalog OutputInputs: Sensor Head Input Inputs: External Input (Auto-Reference Function/Remote Zero-Adjustment Function) DisplayDisplay: Displayable Pressure RangeOperation Indicator ProtectionAmbient TemperatureAmbient HumidityVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceTemperature Characteristics MaterialConnecting MethodCable LengthWeight (Typ.)AccessoriesRemark
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
NPN open-collector transistor (2 outputs)
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and 0 V)
・Residual voltage : 2 V or less (at 100 mA sink current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated

・Output current : 1 to 5 V DC
・Zero point : within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span : within 4 V ± 0.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Output impedance : 1 kΩ approx.


・Output current : 4 to 20 mA
・Zero point : within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span : within 16 mA ± 1.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Load resistance : 250 Ω (max.).
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +0.4 V DC or less
OFF voltage : +5 to +30 V DC, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
PNP open-collector transistor (2 outputs)
・Maximum source current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and +V)
・Residual voltage : 2 V or less (at 100 mA source current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated

・Output current : 1 to 5 V DC
・Zero point : within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span : within 4 V ± 0.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Output impedance : 1 kΩ approx.


・Output current : 4 to 20 mA
・Zero point : within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span : within 16 mA ± 1.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Load resistance : 250 Ω (max.).
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +5 V to +V DC
OFF voltage : +0.6 V DC or less, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
PNP open-collector transistor (2 outputs)
・Maximum source current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and +V)
・Residual voltage : 2 V or less (at 100 mA source current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated

・Output current : 1 to 5 V DC
・Zero point : within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span : within 4 V ± 0.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Output impedance : 1 kΩ approx.


・Output current : 4 to 20 mA
・Zero point : within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span : within 16 mA ± 1.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Load resistance : 250 Ω (max.).
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +5 V to +V DC
OFF voltage : +0.6 V DC or less, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
EMC Directive, RoHS Directive
Gauge pressure
DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head.
DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head.
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Same as supply voltage
NPN open-collector transistor (2 outputs)
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less
(between comparative output and 0 V)
・Residual voltage : 2 V or less (at 100 mA sink current)
NO / NC, selectable by key operation
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable)(however, 2 digits when using psi unit)
With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
With compound pressure type connected : within ±0.2 % F.S. (±4 digits)
0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated

・Output current : 1 to 5 V DC
・Zero point : within 1 V ± 0.5 % F.S.
(vacuum / positive pressure type)
within 3 V ± 0.5 % F.S. (compound pressure type)
・Span : within 4 V ± 0.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Output impedance : 1 kΩ approx.


・Output current : 4 to 20 mA
・Zero point : within 4 mA ± 1 % F.S.
(vacuum / positive pressure type)
within 12 mA ± 1.5 % F.S. (compound pressure type)
・Span : within 16 mA ± 1.5 % F.S.
・Linearity : within ±0.1 % F.S.
・Load resistance : 250 Ω (max.).
Input voltage range : 1 to 5 V DC (over rated pressure range)
ON voltage : +0.4 V DC or less
OFF voltage : +5 to +30 V DC, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Vacuum pressure : +5.1 to -101.3 kPa,
Positive pressure : -0.050 to +1.020 MPa,
Compound pressure : -101.3 to +105.0 kPa
Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connector
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx.
CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.