| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 200 mm 7.874 in | ±80 mm 3.150 in | 200 μm 7.874 mil | ±0.2 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø300 μm 11.811 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 50 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 200 mm 7.874 in | ±80 mm 3.150 in | 200 μm 7.874 mil | ±0.2 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø300 μm 11.811 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 80 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 30 mm 1.181 in | ±5 mm 0.197 in | 10 μm 0.394 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø50 μm 1.969 mil approx | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 80 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 50 mm 1.969 in | ±15 mm 0.591 in | 30 μm 1.181 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø70 μm 2.756 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 80 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 100 mm 3.937 in | ±35 mm 1.328 in | 70 μm 2.756 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø120 μm 4.724 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 50 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 100 mm 3.937 in | ±35 mm 1.328 in | 70 μm 2.756 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø120 μm 4.724 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 80 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 400 mm 15.748 in | ±200 mm 7.874 in | 300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | ±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø500 μm 19.685 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 80 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 50 mm 1.969 in | ±15 mm 0.591 in | 30 μm 1.181 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø70 μm 2.756 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 50 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 30 mm 1.181 in | ±5 mm 0.197 in | 10 μm 0.394 mil | ±0.1 % F.S. | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø50 μm 1.969 mil approx | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 50 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification | 400 mm 15.748 in | ±200 mm 7.874 in | 300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in) 800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | ±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in) ±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in) | 0.03%F.S./℃ | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). | ø500 μm 19.685 mil approx. | 24 V DC ±10 % Ripple P-P 10 % | 40 mA or less (at 24 V DC supply voltage) | IO-Link Specification V1.1 | COM3 (230.4 kbps) | 4 byte | 1.0 ms | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less | Switchable between either Light-ON or Dark-ON | Incorporated (auto reset type) | Switchable between 1.5 ms / 5 ms / 10 ms | 2 | 2,000 m 6561.680 ft or less | IP67(IEC) | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 ℓx or less at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. | Enclosure: Aluminum die-cast, Front cover: Acrylic | 30 g approx. (without cable), 50 g approx. (including cable) | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |