Specifications table for model SF-AC
ItemPerformance characteristics
Connectable Safety Light CurtainsPNP output (equivalent) type light curtains (SF4B-x, SF4-AHx, SF2-Ax-PN, SF2-Nx-PN, SF2-EHx)
Dummy1 A / 24 V DC
Control CategoryISO 13849-1 (EN 954-1) compliance up to Category 4 standards
Power Voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Power Supply for Light Curtain 24V DC plus or minus 10 %
Fuse RatingHybrid fuse, triggering current: 1.1 A or more, Reset after power down
OSSD Input PNP transistor 2 inputs (S1, S2)
Safety OutputNO contact x 3 (13-14, 23-24, 33-34)
Safety Output: Application CategoryAC-15, DC-13 (EN 60947-5-1)
Safety Output: Rated Operation Voltage (Ue)/Rated Operation Current (le)6 A / 30 V DC, 6 A / 230 V AC, resistive load
(Note) The rated operational current (le) varies depending on the ambient temperature. Refer to the below figure.
Safety Output: Contact Material/Contacts AgSnO, Self cleaning, positively driven
Safety Output: Contact Resistance100 mOhm or less (initial value)
Safety Output: Contact Protection Fuse Rated6 A (slow blow)
Safety Output: Mechanical Lifetime10 million times (switching frequency 180 times/min.)
Safety Output: Electrical Lifetime100,000 times (switching frequency 20 times/min, rated load)
Response Time10 ms or less
Auxiliary OutputsNC contact x 1 (41-42)
Auxiliary Output: Contact Protection Fuse Rated1 A (slow blow)
Alarm OutputNC contact x 1 (51-52) (Non-safety contact, related to input ''Alarm in'')
(Note) The alarm output is ''open'' when the alarm input from the light curtain is ON.
Alarm Output: Switching CurrentMax. 1 A / 24 V DC, Min. 5 mA / 24 V DC
Alarm Output: Fuse1 A (slow blow)
Environmental Resistance: Degree of ProtectionEnclosure: IP40
Terminal: IP20
Ambient Temperature-10 to +55 degrees +14 to +131 degrees Fahrenheit , Storage: -10 to + 55 degrees +14 to +131 degrees Fahrenheit
Enclosure MaterialEnclosure: Polycarbonate
Weight (Typ.)Net weight: 460 g approx.