Specifications table for model SG-P2020-M-P
ItemPerformance characteristics
Applicable Standards: International StandardISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119
Applicable Standards: JapanJIS B 9705-1, JIS C 0508 1 to 7, JIS B 9961, JIS C 8201-5-2, JIS B 9710
Applicable Standards: Europe (EU)EN ISO 13849-1 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1
Directive ComplianceCE Marking (Machinery Directive, RE Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification (U.S.A., Canada), the U.S.'s radio regulations (FCC), Canada's radio regulations (ICES-003, RSS-310), Singapore's radio regulations (IMDA)
Operating distance : Front / SideSao (OFF→ON): 5 mm 0.197 in, Sar (ON → OFF): 15 mm 0.591 in
Power Voltage 24V DC+10-20% Ripple P-P 10 % or less
Current Consumption30 mA or less
Control Outputs (OSSD 1, OSSD 2)PNP open-collector transistor 2 outputs
• Maximum source current: 100 mA
• Applied voltage: Same as the power supply voltage (PNP output: between control output and 0 V)
• Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable)
• Leakage current: 0.2 mA or less (including power OFF state)
• Maximum load capacity: 0.47 μF
• Load wiring resistance: 3 Ω or less
Control Outputs (OSSD 1, OSSD 2): Operation Mode• When the actuator is detected (safe state): ON
• When the actuator is not detected (unsafe state or lockout state): OFF
• When the switch body (sub) does not detect actuator (series connection): OFF
Control Output (OSSD): Protection CircuitIncorporated
Response Time• For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less
• For multiple units: Time for single unit + 5 ms x (number of connected units - 1)
Check input and outputDedicated communication line between the switch body (standard) and the switch body (sub) (Note)
* It is not for external input and output. (voltage range 0 V to 5 V DC)
(Note) : When using the device as a single unit, connect the check input with the check output.
Number of units connected in series30 units or less (standard 1 unit, sub 29 units)
Pollution Degree 3
Environmental Resistance: Degree of ProtectionIP65(IEC)
Ambient Temperature-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
Ambient Humidity30 to 85 % RH, storage: 30 to 95 % RH
Environmental Resistance: Dielectric Strength Voltage1,000 V AC for one minute between all supply terminals connected together and enclosure
Insulation Resistance20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions
Shock Resistance300 m/s2 (approx. 30 G), 3 times each in X, Y, and Z direction
MaterialSwitch body: PBT, PC, SUS (stainless steel), EPDM
Actuator: PBT, PC
Cable6–core cabtyre cable, 5 m 16.404 ft long
Connected cable length• When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit
• When connecting multiple units in series: Maximum total cable length of 100 m 328.084 ft, maximum cable length of 20 m 65.617 ft between two adjacent units
Weight (Typ.)Switch body (standard): 180 g approx., Actuator : 20 g approx.
Gross weight270 g approx.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃ +73 ℉.

■Transponder specifications
Operating frequency: 125 kHz
Max. transmitter output: 3.33 μW
Applicable Standards: North AmericaCAN/CSA C22.2 No.14, UL508