Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C

A Type 4 - Compact Safety Light Curtain With Improved Environmental Resistance

The Panasonic SF4B-C Compact Safety Light Curtains, with a thickness of only 20 x 27.4mm, come with an ultra-light housing. The combination of a plastic body with a metal inner frame is designed to minimize weight while at the same time increasing the toughness.

The SF4B-C Series is available as a hand protection type with a beam pitch of 20mm, allowing users to detect objects with a diameter as small as 25mm and the arm-protection type with its beam pitch of 40mm which can detect objects of 45mm and larger. Both types offer an operation range of up to 7m. Cable and Connector types are available.

Characteristics

  • Side Mounting Possible To Avoid Dead Zones
  • Very Light Weight Due To Combined Metal/Polycarbonate Housing
  • Compact Dimensions (20 X 27.4mm)
  • Large Multi-Purpose Indicator
  • PNP / NPN Polarity Switching
  • Beam Alignment Indicator
  • Interference Prevention Incorporated
  • IP65 Protection

 

Part Number List

Results 52
Models table for series Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C
Part No.DatasheetNo. of Beam ChannelsProtective Height Current ConsumptionCurrent Consumption: Large Multipurpose Indicator Lights OffCurrent Consumption: Large Multipurpose Indicator Lights UpPFH<sub>D</sub>MTTF<sub>D</sub>Net Weight (Total of Emitter and Receiver) Applicable Standards: International StandardApplicable Standards: JapanApplicable Standards: Europe (EU)Applicable Standards: North AmericaApplicable Standards: South Korea (S-Mark)CE Marking Directive ComplianceOperating RangeBeam PitchMin. Sensing ObjectEffective Aperture AnglePower Voltage Control Outputs (OSSD 1, OSSD 2)Control Outputs (OSSD 1, OSSD 2): Operation ModeControl Outputs (OSSD1, OSSD2): Protection CircuitResponse TimeAuxiliary Output (Non-Safety Output)Auxiliary Output (Non-Safety Output): Operation ModeAuxiliary Output (Non-Safety Output): Protection CircuitMuting Auxiliary Output:Operation ModeMuting Auxiliary OutputMuting Auxiliary Output:Protection CircuitELCA Function Emission Halt FunctionInterlock FunctionExternal Device Monitoring FunctionOverride FunctionMuting Function Large Multi-Purpose Indicator Function Optional FunctionsPollution Degree Operating AltitudeEnvironmental Resistance: Degree of ProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceEnvironmental Resistance: Dielectric Strength VoltageInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialCableCable ExtensionAccessories
12
503.4 mm 19.819 in
Emitter: 60 mA or less
Receiver: 70 mA or less
1.9 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 930 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)

• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)

• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
-
-
-
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
-
-
-
Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to total 50 m 164.042 ft is possible for 0.2 mm2 or more, cable
(Note) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
-
28
1,143.4 mm 45.016 in
Emitter: 70 mA or less
Receiver: 85 mA or less
Emitter: 80 mA or less
Receiver: 95 mA or less
2.9 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 1,300 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
-
16
663.4 mm 26.118 in
Emitter: 65 mA or less
Receiver: 75 mA or less
Emitter: 75 mA or less
Receiver: 85 mA or less
2.2 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 750 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
-
16
663.4 mm 26.118 in
Emitter: 65 mA or less
Receiver: 75 mA or less
2.2 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 1,100 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
-
-
-
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
-
-
-
Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to total 50 m 164.042 ft is possible for 0.2 mm2 or more, cable
(Note) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
-
20
423.4 mm 16.669 in
Emitter: 65 mA or less
Receiver: 75 mA or less
2.4 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 860 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, S2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
-
-
-
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
-
-
-
Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to total 50 m 164.042 ft is possible for 0.2 mm2 or more, cable
(Note) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
SF4B-TR25 (Test rod): 1 pc.
16
343.4 mm 13.52 in
Emitter: 65 mA or less
Receiver: 75 mA or less
Emitter: 75 mA or less
Receiver: 85 mA or less
2.1 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 430 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, S2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
SF4B-TR25 (Test rod): 1 pc.
44
1,783.4 mm 70.212 in
Emitter: 80 mA or less
Receiver: 100 mA or less
Emitter: 90 mA or less
Receiver: 110 mA or less
3.9 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 1,800 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
-
36
1,463.4 mm 57.614 in
Emitter: 75 mA or less
Receiver: 95 mA or less
Emitter: 85 mA or less
Receiver: 105 mA or less
3.4 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 1,600 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
-
12
263.4 mm 10.37 in
Emitter: 65 mA or less
Receiver: 75 mA or less
Emitter: 75 mA or less
Receiver: 85 mA or less
1.9 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 360 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, S2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3Ωor less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
When muting auxiliary output: ON
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m 65.617 ft length cable)
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
Incorporated
Incorporated
Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
Extension up to total 50 m 164.042 ft is possible for both emitter and receiver optional mating cables
SF4B-TR25 (Test rod): 1 pc.
36
1,463.4 mm 57.614 in
Emitter: 75 mA or less
Receiver: 95 mA or less
3.4 × 10-9
(Note) Probability of dangerous failure per hour.
100 years or more
(Note) Mean time to dangerous failure.
approx. 2,000 g
IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06
(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognized safety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
S1-G-35-2005, s2-W-11-2003
Machine Directive, EMC Directive, RoHS Directive
0.3 to 7m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
40 mm 1.575 in
ø 45 mm ø 1.772 in opaque object
(Note) In case the blanking function is valid, the operation mode is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and +V)
• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less


• Maximum sink current: 200 mA
• Applied voltage: Same as supply voltage (between the control output and 0 V)
• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m 65.617 ft length cable)
• Leakage current: 0.1 mA or less (Including power supply OFF condition)
• Maximum load capacity: : 0.22 micro F (No load to maximum output current)
• Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) During muting, control output will not turn off even if the beams are interrupted.
(Note) When the blanking function is enabled, the operating mode will change.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
PNP open-collector transistor / NPN open-collector transistor (switching method)


• Maximum source current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m 65.617 ft length cable)


• Maximum sink current: 60 mA
• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m 65.617 ft length cable)
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Incorporated
-
-
-
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Auto reset]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
-
-
-
Fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing
(Note) In case of using optional function, the handy-controller SFB-HC is required.
3
2,000 m 6,561.68 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65 (IEC)
-10 to +55℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –25 to +60 ℃ –3 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 3,500 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 850 nm 0.033 mil)
Enclosure: Polycarbonate
0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to total 50 m 164.042 ft is possible for 0.2 mm2 or more, cable
(Note) When the synchronization+ wire (orange) and synchronization- wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
-