| | Machinery Directive, EMC Directive, RoHS Directive | 16 | 320 mm 12.598 in | Emitter: 30 mA or less Receiver: 30 mA or less | 3.86 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 40 mA or less Receiver: 35 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 400 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 24 | 480 mm 18.898 in | Emitter: 35 mA or less Receiver: 35 mA or less | 3.99 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 45 mA or less Receiver: 40 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 520 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 24 | 480 mm 18.898 in | Emitter: 35 mA or less Receiver: 35 mA or less | 3.85 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 45 mA or less Receiver: 40 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 520 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 8 | 160 mm 6.299 in | Emitter: 25 mA or less Receiver: 25 mA or less | 3.60 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 35 mA or less Receiver: 30 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 280 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 32 | 640 mm 25.197 in | Emitter: 35 mA or less Receiver: 35 mA or less | 4.12 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 50 mA or less Receiver: 45 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 640 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 12 | 240 mm 9.449 in | Emitter: 30 mA or less Receiver: 30 mA or less | 3.66 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 35 mA or less Receiver: 35 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 340 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 12 | 240 mm 9.449 in | Emitter: 30 mA or less Receiver: 30 mA or less | 3.80 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 35 mA or less Receiver: 35 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 340 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 16 | 320 mm 12.598 in | Emitter: 30 mA or less Receiver: 30 mA or less | 3.73 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 40 mA or less Receiver: 35 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 400 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 20 | 400 mm 15.748 in | Emitter: 35 mA or less Receiver: 35 mA or less | 3.93 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 40 mA or less Receiver: 40 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 460 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| | Machinery Directive, EMC Directive, RoHS Directive | 20 | 400 mm 15.748 in | Emitter: 35 mA or less Receiver: 35 mA or less | 3.79 × 10-9 (Note) Probability of dangerous failure per hour. | Emitter: 40 mA or less Receiver: 40 mA or less | 100 years or more (Note) Mean time to dangerous failure. | 460 g approx. | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. | 0.1 to 3 m 0.328 to 9.843 ft | 20 mm 0.787 in | ø25 mm ø0.984 in opaque object | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] | 24 V DC plus or minus 20 % Ripple P-P 10 % or less | - Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) | Incorporated | OFF response: 20 ms or less ON response: 80 to 100 ms | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. | Incorporated | Incorporated | Incorporated | Incorporated | 3 | 2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. | IP65, IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉ | Incandescent light: 5,000 ℓx or less at the light-receiving face | 30 to 85 % RH, Storage: 30 to 85 % RH | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 850 nm 0.034 mil) | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | Extension up to total 50m is possible for 0.3mm2 or more, cable | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |