Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Ultra Slim Safety Light Curtain With LED Indicators, Type 4
The SF4C Series Ultra-Slim Safety Light Curtain has been designed to offer a safeguarding solution for machines to make them safe for the operators without sacrificing productivity. The ultra-slim size and shape of the SF4C Series (13mm) allow it to fit efficiently into small machinery while maximizing the usable working space for the equipment operator.
SF4C Series is an Ultra-Slim Safety Light Curtain with large LED bars on each side of the Light Curtain. The LED bars provide a large, visible indicator that can be customized for various applications with the help of independent external inputs. The indicator can be used as an operation indicator, as an error indicator or as a muting lamp.
Characteristics
Large Built-In Multi-Purpose LED Indicators
Auto-Interference Prevention = ELCA Function
4 Blocks Of Beam-Axis Adjustment Indicators
Digital Error Display
Output Polarity Setting
IP67 Protection
Fast Response Time Of 7ms For All Models
Various Blanking Functions
Manual Reset / Auto Reset
External Device Monitor
Override Function
New! 2 N.C. Safety Inputs
New! Various Muting Functions (e.g. Exit Muting Control)
Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Part number list
Results 31
Models table for series Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Part No.
Datasheet
No. of Beam Channels
Protective Height
Current Consumption: Large Multipurpose Indicator Lights Off
Current Consumption: Large Multipurpose Indicator Lights Up
PFHD
MTTFD
Net Weight (Total of Emitter and Receiver)
Applicable Standards: International Standard
Applicable Standards: Japan
Applicable Standards: Europe (EU)
Applicable Standards: North America
Operating Range
Beam Pitch
Min. Sensing Object
Effective Aperture Angle
Power Voltage
Control Outputs (OSSD 1, OSSD 2)
Control Outputs (OSSD 1, OSSD 2): Operation Mode
Control Outputs (OSSD1, OSSD2): Protection Circuit
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft (Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 200 mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
[When selecting NPN output] - Max. sink current: 200 mA - Applied voltage: same as supply voltage (between the control output and 0 V) - Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) - Leakage current: 200 micro A or less (including power supply OFF condition) - Max. load capacity: 1 micro F (No load to Max. output current) - Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method) [When selecting PNP output] - Max. source current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and +V) - Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
[When selecting NPN output] - Max. sink current: 100 mA - Applied voltage: same as supply voltage (between the auxiliary output and 0 V) - Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated [Manual reset / Automatic reset (Note)] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting (Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable. (Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).