There are more the 40 different models in the Safety Light Curtain SF4B Series and their modular design makes them easy to expand. These compact, Type 4 Safety Light Curtains comply with EN 61496-1 /-2 and EN ISO 13849 performance level (PLe). The SF4B Series are available in three (3) different beam pitches (10 mm, 20 mm and 40 mm) and in numerous sensing heights.
The SF4B Series offers flexibility and a wide range of accessories such as mounting brackets and extension cables. Cables for Series connection are also available to eliminate dead zones. The SF4B Series can now be equipped with corner mirrors to reduce setup work and wiring.
Part No. | Datasheet | CE Marking Directive Compliance | No. of Beam Channels | Protective Height | Protective Height: China Press Compliant (GB/T 4584) | Current Consumption | PFHD | MTTFD | Weight (Total Of Emitter And Receiver) | Applicable Standards: International Standard | Applicable Standards: Japan | Applicable Standards: Europe (EU) | Applicable Standards: North America | Applicable Standards: South Korea (S-Mark) | Applicable Standards: China (GB) | Operating Range | Min. Sensing Object | Effective Aperture Angle | Power Voltage | Control Outputs (OSSD 1, OSSD 2) | Control Outputs (OSSD 1, OSSD 2): Operation Mode | Control Outputs (OSSD1, OSSD2): Protection Circuit | Response Time | Auxiliary Output (Non-Safety Output) | Auxiliary Output (Non-Safety Output): Operation Mode | Auxiliary Output (Non-Safety Output): Protection Circuit | Interference Prevention Function | Auxiliary Output (Non-Safety Output): Response Time | Emission Halt Function | Interlock Function | External Device Monitoring Function | Override Function | Muting Function | Optional Functions | Environmental Resistance: Degree of Protection | Ambient Temperature | Environmental Resistance: Dielectric Strength Voltage | Ambient Humidity | Ambient Illuminance | Vibration Resistance | Insulation Resistance | Shock Resistance | Emitting Element | Material | Connecting Method | Cable Length | Accessories | Applicable Standards: China |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Machinery Directive, EMC Directive, RoHS Directive | 12 | 470 mm 18.504 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 440mm 17.323 in | Emitter: 70 mA or less Receiver: 95 mA or less | 1.8 × 10-9 | 100 years or more | 960 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø45 mm ø1.772 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | |||
Machinery Directive, EMC Directive, RoHS Directive | 10 | 390 mm 15.354 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 360mm 14.173in | Emitter: 65 mA or less Receiver: 85 mA or less | 1.7 × 10-9 | 100 years or more | 810 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø45 mm ø1.772 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | |||
Machinery Directive, EMC Directive, RoHS Directive | 14 | 550 mm 21.654 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 520 mm 20.472 in | Emitter: 70 mA or less Receiver: 95 mA or less | 1.9 × 10-9 | 100 years or more | 1,110 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø45 mm ø1.772 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | |||
Machinery Directive, EMC Directive, RoHS Directive | 12 | 470 mm 18.504 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 440mm 17.323 in | Emitter: 70 mA or less Receiver: 95 mA or less | 1.8 × 10-9 | 100 years or more | 960 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø45 mm ø1.772 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | |||||
Machinery Directive, EMC Directive, RoHS Directive | 127 | 1,270 mm 50.000 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,260mm 49.606 in | Emitter: 135 mA or less Receiver: 230 mA or less | 7.6 × 10-9 | 100 years or more | 2,470 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR14 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 47 | 470 mm 18.504 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 460mm 18.110 in | Emitter: 100 mA or less Receiver: 160 mA or less | 3.6 × 10-9 | 100 years or more | 960 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | SF4B-TR14 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 23 | 230 mm 9.055 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 220mm 8.661 in | Emitter: 80 mA or less Receiver: 120 mA or less | 2.4 × 10-9 | 100 years or more | 510 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | SF4B-TR14 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||
Machinery Directive, EMC Directive, RoHS Directive | 127 | 1,270 mm 50.000 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 1,260mm 49.606 in | Emitter: 135 mA or less Receiver: 230 mA or less | 7.6 × 10-9 | 100 years or more | 2,470 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | MS-SFB-2 (Intermediate supporting bracket): 2 sets SF4B-TR14 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 39 | 390 mm 15.354 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 380mm 14.960 in | Emitter: 80 mA or less Receiver: 120 mA or less | 3.2 × 10-9 | 100 years or more | 810 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 7 m 0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø14 mm ø0.551 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | SF4B-TR14 (Test rod): 1 No | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | ||||
Machinery Directive, EMC Directive, RoHS Directive | 8 | 310 mm 12.205 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".) | 280mm 11.024 in | Emitter: 65 mA or less Receiver: 85 mA or less | 1.6 × 10-9 | 100 years or more | 660 g approx. | IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) (Note) PLe SIL3 compliant from production in August 2009. | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) PLe SIL3 compliant from production in August 2009. | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 (Note) PLe SIL3 compliant from production in August 2009. | S1-G-35-2005, S2-W-11-2003 (Note) PLe SIL3 compliant from production in August 2009. | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. | 0.3 to 9 m 0.984 to 29.528 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. | ø45 mm ø1.772 in opaque object (Note) When the floating blanking function is used, the size of the min. sensing object is changed. | plus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable) | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped. (Note) In case the blanking function is valid, the operation mode is changed. | Incorporated | OFF response: 14 ms or less, ON response: 80 to 90 ms | PNP open-collector transistor / NPN open-collector transistor (switching method) - When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA - Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V) - Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable) | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)). | Incorporated | Incorporated (Note) Please use 12-core cable. | OFF replay: 34 ms or less, ON replay 110 ms or less | Incorporated | Incorporated [Manual reset / Auto reset (Note)] (Note) The manual reset and auto reset are possible to be switched depending on the wiring status. | Incorporated | Incorporated (Note) Please use 12-core cable. | Incorporated (Note) Please use 12-core cable. | Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control (Note) In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-x-01 and the SF-C14EX-01. | IP67 / IP65 (IEC) | -10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉ | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 30 to 85 % RH, Storage: 30 to 95 % RH | Incandescent light: 3,500 lx or less at the light-receiving face | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 870 nm 0.034 mil) | Enclosure: Aluminium Upper and lower edges: Iron Sensing surface: Polycarbonate / Polyester resin Cap: PBT | Connector | Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables (Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver). | GB/T 4584 (Note) PLe SIL3 compliant from production in August 2009. |