Specification

Specifications table for model SF-C14EX-01
ItemPerformance characteristics
Connectable Safety Light CurtainsSF4B / SF4B-G series
(Note:The handy-controller SFB-HC (optional) cannot be used with SF-C14EX-01.)
Applicable Standards: International StandardIEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
CE Marking Directive ComplianceMachinery Directive, EMC Directive, RoHS Directive
Control CategoryISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Applicable Standards: JapanJIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
Applicable Standards: Europe (EU)EN 55011, EN ISO 13849-1 (Category 4, PLe)
Applicable Standards: North AmericaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Power Voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current Consumption0.2 A or less (Excluding Safety light curtain and other external connecting device)
Safety Outputs (Safety Output 1, Safety Output 2, Safety Output 3) PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)

・Maximum source current: 200 mA
・Applied voltage: same as supply voltage
(between the safety output and +V)
・Residual voltage: 2 V or less (at 200 mA source current)

・Maximum sink current: 200 mA
・Applied voltage: same as supply voltage
(between the safety output and 0 V)
・Residual voltage: 2 V or less (at 200 mA sink current)
Safety Outputs (Safety Output 1, Safety Output 2, Safety Output 3): Operation Mode (Output Operation)Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)
Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is valid
OFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)
Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Safety Outputs (Safety Output 1, Safety Output 2, Safety Output 3): Protection Circuit (Short-Circuit Protection) Incorporated
Safety Outputs (Safety Output 1, Safety Output 2, Safety Output 3): Response Time OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the light curtain)
ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)
(Note) The auto-reset cannot be used with safety output 3.
Auxiliary Outputs (Auxiliary Output 1, Auxiliary Output 2, Auxiliary Output 3, Auxiliary Output 4)PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)

・Maximum source current: 60 mA
・Applied voltage: same as supply voltage
(between the auxiliary output and +V)
・Residual voltage: 2 V or less (at 60 mA source current)

・Maximum sink current: 60 mA
・Applied voltage: same as supply voltage
(between the auxiliary output and 0 V)
・Residual voltage: 2 V or less (at 60 mA sink current)
Auxiliary Outputs (Auxiliary Output 1, Auxiliary Output 2, Auxiliary Output 3, Auxiliary Output 4): Operation Mode (Output Operation)Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid
Auxiliary output 2: ON when the override function is invalid, OFF when the override function is valid
Auxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error
Auxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition
(Note:The auxiliary output incorporated in the SF4B series is output.)
Auxiliary Outputs (Auxiliary Output 1, Auxiliary Output 2, Auxiliary Output 3, Auxiliary Output 4):Protection Circuit (Short-Circuit Protection)Incorporated
Muting Lamp OutputApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Muting Lamp Output:Protection CircuitIncorporated
PFH<sub>D</sub>1.66 × 10-10
(Note:Probability of dangerous failure per hour)
MTTF<sub>D</sub>100 years or more
(Note:Mean time to dangerous failure (in years))
Environmental Resistance: Degree of ProtectionEnclosure: IP40
Terminal: IP20
Ambient Temperature-10 to +55 ℃ +14 to +131
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158 ℉
Environmental Resistance: Dielectric Strength Voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Ambient Humidity30 to 85 % RH, Storage: 30 to 95 % RH
Insulation Resistance20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance30 G acceleration in X, Y and Z directions three times each
MaterialEnclosure: ABS
Connection TerminalDetachable spring-cage terminal
Weight (Typ.)Net weight: 250 g approx.

Stock Check