Specifications table for model SG-B1-MB-G1
ItemPerformance characteristics
Main Contacts1NC + 1NC
Door Monitor Contacts2NC
Lock Monitor Contacts1NO
Cable Length1m 3.281 ft
Applicable StandardsEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-19, UL 508, CSA C22.2 No.14
Applicable Standards: Standards For UseIEC 60204-1, EN 60204-1
Applicable DirectivesMachinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
Operating Condition: Ambient Temperature -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
Operating Condition: Ambient Humidity 45 to 85 % RH
Operating Condition: Pollution Degree S3 (Inside 2)
Operating Condition: Altitude 2,000 m 6,561.68 ft max.
Rated Insulation Voltage (Ui)300 V (Door monitor circuit)
150 V (Main, Lock monitor circuit)
30 V (Between ground and LED, solenoid circuit)
Impulse Withstand Voltage (Uimp)2.5 kV (Door monitor circuit)
1.5 kV (Main, Lock monitor circuit)
0.5 kV (Between ground and LED, solenoid circuit)
Thermal Current (Ith)・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉
2.5 A (up to 2 circuits)
1.0 A (3 or more circuits)
・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉
1.0 A (1 circuit)
0.5 A (2 or more circuits)
Rated Operational Voltage (Ue)/Rated Operational Current (Le)
  Ue
  30V 125V 250V
Ie Main circuit, look monitor circuit AC Resistive load (AC-12) - 2A -
Inductive load (AC-15) - 1A -
DC Resistive load (DC-12) 2A 0.4A -
Inductive load (DC-13) 1A 0.22A -
Door monitor circuit AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (AC-15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Electric Shock Protection ClassClass II (IEC 61140)(Note), 回(double insulated)
(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Operating Frequency900 operations/hour
Actuator Operating Speed0.05 to 1.0 m/sec.
B10D2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical Durability1,000,000 operations min. (GS-ET-19)
Electrical Durability100,000 operations min.
(900 operations/hour,
AC-12 125 V 2A, DC-12 125 V 0.4 A)
1,000,000 operations min.
(900 operations/hour,
24 V AC/DC 0.1 A resistive load)
Interlock Force500 N min. (GS-ET-19)
(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.
Do not apply a load higher than the rated value.
When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Direct Opening Travel8 mm 0.315 in min.
Direct Opening Force60 N min.
Contact Resistance300 mΩ max. (initial value, 1 m 3.281 ft cable)
700 mΩ max. (initial value, 5 m 16.404 ft cable)
ProtectionIP 67 (IEC 60529)
Shock ResistanceMalfunction : 100 m/s2, Destruction : 1,000 m/s2
Vibration ResistanceMalfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in
Short-Circuit Protective DeviceUse 250 V / 10 A fast acting type fuse
MaterialEnclosure : PA66
CableUL style 2464, No.22 AWG 12-core
Solenoid/Indicator: Rated Operating VoltageDC 24 V 100% duty cycle
Solenoid/Indicator: Rated Current110 mA (solenoid 100 mA, LED 10 mA : initial value)
Solenoid/Indicator: Turn on VoltageRated voltage × 85 % max. (at 20 ℃ 68 ℉)
Solenoid/Indicator: Turn Off VoltageRated voltage × 10 % min. (at 20 ℃ 68 ℉)
Solenoid/Indicator: Indicator Green LED
Weight (Typ.)Approx. 220 g
DummyCE Marking [Machinery Directive(2006/42/EC), RoHS Directive], UKCA Marking [Machinery Regulations(2008 No.1597), RoHS Regulations]

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.