| | | 2NO/2NC (22) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 95 g | Key : 2pcs., Lever lock : 1 pc. |
| | | 1NO/1NC (11) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 75 g | Key : 2pcs., Lever lock : 1 pc. |
| | | 1NO/1NC (11) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 75 g | Key : 2pcs., Lever lock : 1 pc. |
| | | 2NO/2NC (22) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 95 g | Key : 2pcs., Lever lock : 1 pc. |
| | | 1NO/1NC (11) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 75 g | Key : 2pcs., Lever lock : 1 pc. |
| | | 2NO/2NC (22) | | JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | -25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 | 2,000 m 6,561.68 ft max. | 4 kV | 600 V | 10 A |
|
Ue |
24V |
48V |
50V |
110V |
220V |
440V |
Ie |
AC |
Resistive load (AC-12) |
10A |
- |
10A |
10A |
6A |
2A |
Inductive load (AC-15) (A600) |
10A |
- |
7A |
5A |
3A |
1A |
DC |
Resistive load (DC-12) |
8A |
4A |
- |
2.2A |
1.1A |
- |
Inductive load (DC-13) (P600) |
4A |
2A |
- |
1.1A |
0.6A |
- |
| 100 MΩ min. (500 V DC megger) | 50 mΩ max. (initial value) | Class II(IEC 61140) | Front of the panel : IP65 | II(IEC 60664-1) | Malfunction : 100 m/s2, Destruction : 1,000m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 100,000 (ISO 13849-1 Annex C Table C.1) | 100,000 operations min. | 100,000 operations min. (1,200 operations/hour) | Actuator : PA6, Contact block : PA66 | Terminal screw (M3.5 philips & flathead ) | Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. | 1.0 to 1.3 N・m | 2.0 N・m | 2 positions | 90° | 0.4 N・m | 90° | Approx. 95 g | Key : 2pcs., Lever lock : 1 pc. |