Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | Machinery Directive, EMC Directive, RoHS Directive |
Applicable Standards: International Standard | ISO 13849-1 (Category 4, PLe), IEC 60947-5-2, IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3) |
Applicable Standards: Japan | JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) |
Applicable Standards: Europe (EU) | EN 60947-5-2, EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3) (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
Applicable Standards: South Korea | S1-G-1-2009, S2-W-5-2009 |
Applicable Standards: SEMI | Conforming to SEMI-S2-0310a |
Power Voltage | 24 V DC+10-15 % Ripple P-P 10 % or less |
Current Consumption | 200 mA or less |
Control Outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 200 mA - Applied voltage: Same as power voltage (between control output to +V) - Residual voltage: 2.5 V or less (at 200 mA source current) [Selecting NPN output] - Maximum sink current: 200 mA - Applied voltage: Same as power voltage (between control output to 0 V) - Residual voltage: 2.0 V or less (at 200 mA sink current) |
Control Outputs (OSSD 1, OSSD 2): Operation Mode | ON when normal condition or initial detection, OFF when detection leakage or wrong installation |
Control Output (OSSD 1, OSSD 2): Response Time | 20 ms or less (excluding the response time of the sensor) |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 60 mA - Applied voltage: Same as power voltage(between sensor monitor output to +V) - Residual voltage: 2.5 V or less (at 60 mA source current) [Selecting NPN output] - Maximum sink current: 60 m A - Applied voltage: Same as power voltage(between sensor monitor output to 0 V) - Residual voltage: 2.0 V or less (at 60 mA sink current) |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output): Operation Mode (Output Operation) | ON when normal condition, OFF when initial detection or accidental leakage |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output): Response Time | 100 ms or less (excluding the response time of the sensor) |
Lockout Output | OFF for lockout (Rating: Same as sensor monitor output) |
Protection | IP20 (IEC) (However, it should be in IP54 protection structure of control panel) |
Function | Interlock / lockout cancel / Test input / External device monitor / Safety input / Control output polarity selection / Non-safety output polarity selection / Sensor connection number setting |
Auxiliary Output | Negative logic output of control output 1 / 2 (OSSD 1 / 2) (Rating: Same as sensor monitor output) [Auxiliary output ON when control output 1 / 2 (OSSD 1/2) is OFF] |
Ambient Temperature | -10 to +55 ℃ +14 to +131℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
PFH<sub>D</sub> | 2.55 x 10-9 (when connecting 4 safety liquid connecting sensors) |
MTTF<sub>D</sub> | 100 years or more |
Material | Main unit case: PC + ABS (alloy) |
Weight (Typ.) | Net weight: 170 g approx Gross weight: 440 g approx |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.