High-quality 3.8" Monochrome Display with high resolution and improved readability. Offered in eight (8) different models that are all IoT capable due to a built-in ethernet port.
Features:
3-Color LED Backlight
480 x 192 Resolution
SD Memory Card Slot
IP67 Rating
GT703
Part number list
Results 16
Models table for series GT703
Part No.
Datasheet
CE Marking Directive Compliance
Power Supply
Communication Port
Operating Voltage Range
Power Consumption
Power Supply Unit Isolation Method
Ambient Temperature
Ambient Humidity
Storage Temperature
Storage Humidity
Vibration Resistance
Shock Resistance
Superposed Noise Suppression
Environmental Resistance
Net Weight
Display: Display Device
Display: Resolution
Display: Display Color
Display: Displayable Area
Display: Backlight
Functions: Font Types
Functions: Languages
Functions: Graphics
Functions: Number of Screens
Functions: Screen Setting No.
Functions: Part Functions
Functions: Other Functions
Functions: Clock Function
Functions: Backlight Brightness Adjustment
Functions: Contrast Adjustment
Functions: Buzzer
Functions: Automatic Communication Settings
Functions: Through Function
Functions: Screen Creation
Touch Key Resolution
Touch Key Operation Force
Touch Key Life
COM. Port: External Communication Conditions
COM. Port: Communication Standard
COM. Port: Protocol
COM. Port: Connector
Screen Data Transfer Interface: Communication Standard
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
Models table for series GT703
Part No.
Datasheet
CE Marking Directive Compliance
Power Supply
Communication Port
Operating Voltage Range
Power Consumption
Power Supply Unit Isolation Method
Ambient Temperature
Ambient Humidity
Storage Temperature
Storage Humidity
Vibration Resistance
Shock Resistance
Superposed Noise Suppression
Environmental Resistance
Net Weight
Display: Display Device
Display: Resolution
Display: Display Color
Display: Displayable Area
Display: Backlight
Functions: Font Types
Functions: Languages
Functions: Graphics
Functions: Number of Screens
Functions: Screen Setting No.
Functions: Part Functions
Functions: Other Functions
Functions: Clock Function
Functions: Backlight Brightness Adjustment
Functions: Contrast Adjustment
Functions: Buzzer
Functions: Automatic Communication Settings
Functions: Through Function
Functions: Screen Creation
Touch Key Resolution
Touch Key Operation Force
Touch Key Life
COM. Port: External Communication Conditions
COM. Port: Communication Standard
COM. Port: Protocol
COM. Port: Connector
Screen Data Transfer Interface: Communication Standard
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-422/RS-485
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
2 W or less Note: Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages) (Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
180 g approx.
TFT monochrome LCD
480 (W) × 192 (H) dots
2 colors (black / white, 64-gray scale)
88.5 (W) × 35.4 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height. True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
250 screens approx. (Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.) *Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC. (There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10. Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Conforms to RS-232C
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation (Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)