The FP7 Series offers high performance and functionality in a compact design. Advanced features and expandable intelligent units make it an ideal choice for various Industrial Automation applications.
Key Features
Connect Up To 64 Different Expansion Units
Add On Cassettes Expands Functionality (Communication And Analog I/O) Without Increasing Footprint
24V, 5V DC Terminals And A RS232 Communication Port On All CPUs
Built-In Ethernet Port Supports Modbus TCP, MEWTOCOL, And Ethernet/IP Implicit Messaging. Up To 272 Connections Can Be Active Simultaneously
Fieldbus Units Available: Profibus, Profinet, CANOpen, DeviceNet, and EtherCAT Motion Controller
Built-In Webserver With Preset System Webpage
Up To 35 Serial Communication Channels Are Possible
SD Data Logging Capability (Up To 32GB)
HTTP And FTP Client Functions (SSL-Compatible)
FP7
Part number list
Results 10
Models table for series FP7
Part No.
Datasheet
Memory Capacity: Memory Selection Pattern 1
Memory Capacity: Memory Selection Pattern 2
Memory Capacity: Memory Selection Pattern 3
Memory Capacity: Memory Selection Pattern 4
Memory Capacity: Memory Selection Pattern 5
Programming Method
Method
Program Memory
Operation Speed
External Input (X)
External Output (Y)
Internal Relay (R)
System Relay (SR)
Link Relay (L)
Timer (T)
Counter (C) (C)
Link Data Register (LD)
System Data Register (SD)
Index Register (I0 to IE)
Master Control Relay (MCR)
Number of Labels (LOOP)
Differential Points
Number of Step Ladders
Number of Subroutines
Number of Interrupt Program
SD Memory Card Function
Real Time Clock
Battery Life (Value Applies When No Power Is Supplied At All.)
Program (steps): 234,000 Data register (Note) : 65,536 Number of max. program block (PB): 468 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500 Data register (Note) : 131,072 Number of max. program block (PB): 443 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000 Data register (Note 1): 262,144 Number of max. program block (PB): 392 (Note) The factory default setting is pattern 3. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500 Data register (Note) : 524,288 Number of max. program block (PB): 289 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500 Data register (Note) : 999,424 Number of max. program block (PB): 103 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 234,000 Data register (Note) : 65,536 Number of max. program block (PB): 468 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500 Data register (Note) : 131,072 Number of max. program block (PB): 443 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000 Data register (Note 1): 262,144 Number of max. program block (PB): 392 (Note) The factory default setting is pattern 3. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500 Data register (Note) : 524,288 Number of max. program block (PB): 289 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500 Data register (Note) : 999,424 Number of max. program block (PB): 103 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps)(Note) : 64,000 Data register (words)(Note) : 131,072 Number of max. program block (PB) : 128 (Note) The factory default setting is pattern 1. (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps)(Note) : 32,000 Data register (words)(Note) : 262,144 Number of max. program block (PB) : 64 (Note1) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 14 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 μs, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MΩ or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 μs (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
150 mA or less
180 g approx. (with terminal block and end unit)
Models table for series FP7
Part No.
Datasheet
Memory Capacity: Memory Selection Pattern 1
Memory Capacity: Memory Selection Pattern 2
Memory Capacity: Memory Selection Pattern 3
Memory Capacity: Memory Selection Pattern 4
Memory Capacity: Memory Selection Pattern 5
Programming Method
Method
Program Memory
Operation Speed
External Input (X)
External Output (Y)
Internal Relay (R)
System Relay (SR)
Link Relay (L)
Timer (T)
Counter (C) (C)
Link Data Register (LD)
System Data Register (SD)
Index Register (I0 to IE)
Master Control Relay (MCR)
Number of Labels (LOOP)
Differential Points
Number of Step Ladders
Number of Subroutines
Number of Interrupt Program
SD Memory Card Function
Real Time Clock
Battery Life (Value Applies When No Power Is Supplied At All.)
Program (steps): 234,000 Data register (Note) : 65,536 Number of max. program block (PB): 468 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500 Data register (Note) : 131,072 Number of max. program block (PB): 443 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000 Data register (Note 1): 262,144 Number of max. program block (PB): 392 (Note) The factory default setting is pattern 3. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500 Data register (Note) : 524,288 Number of max. program block (PB): 289 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500 Data register (Note) : 999,424 Number of max. program block (PB): 103 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 234,000 Data register (Note) : 65,536 Number of max. program block (PB): 468 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500 Data register (Note) : 131,072 Number of max. program block (PB): 443 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000 Data register (Note 1): 262,144 Number of max. program block (PB): 392 (Note) The factory default setting is pattern 3. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500 Data register (Note) : 524,288 Number of max. program block (PB): 289 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500 Data register (Note) : 999,424 Number of max. program block (PB): 103 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 254 units
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3 Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
Program (steps)(Note) : 64,000 Data register (words)(Note) : 131,072 Number of max. program block (PB) : 128 (Note) The factory default setting is pattern 1. (Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps)(Note) : 32,000 Data register (words)(Note) : 262,144 Number of max. program block (PB) : 64 (Note1) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 14 ns/step
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 μs, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits.
Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MΩ or more (at 500 V DC)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
1,000 V [p-p] with pulse width 50 ns and 1 μs (using a noise simulator)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions