| | Relay symbol / Cyclic operation | 10 points [Input : 6, Relay output : 4] | Max. 58 points (Note: For the limitations while operating units, reter to the manual.) | Max. 106 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | One RS-232C port is mounted (3P terminal block) Transmission speed (Baud rate) : 2,400 to 115,200 bits/s, Transmission distance : 15 m 9.843 ft. Communication method : half duplex | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 2 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |
| | Relay symbol / Cyclic operation | 16 points [Input : 8, Transistor output : 8] | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | 4 points (50 kHz max. each) 2 channels can be controlled individually. (Note: For the limitations while operating units, reter to the manual.) | 4 points (6 Hz to 4.8 kHz) | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | One RS-232C port is mounted (3P terminal block) Transmission speed (Baud rate) : 2,400 to 115,200 bits/s, Transmission distance : 15 m 9.843 ft. Communication method : half duplex | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 8 points / common | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 20 μs or less (Load current : 5 mA or more), 0.1 ms or less (Load current : 0.5 mA or more) | 40 μs or less (Load current : 5 mA or more), 0.2 ms or less (Load current : 0.5 mA or more) | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | Open collector | | 5 to 24 V DC | 4.75 to 26.4 V DC | 0.2 A / point (Max. 14 per common terminal) | 1 μA or less | 0.2 V DC or less | | | 21.6 to 26.4 V DC | 30 mA or less | Zener diode | Photocoupler |
| | Relay symbol / Cyclic operation | 16 points [Input : 8, Transistor output : 8] | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | 4 points (50 kHz max. each) 2 channels can be controlled individually. (Note: For the limitations while operating units, reter to the manual.) | 4 points (6 Hz to 4.8 kHz) | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | One RS485 port is mounted (3P terminal block) Transmission speed (Baud rate) : 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance : 1,200 m 3,937 ft, Communication method : half duplex | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 8 points / common | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 20 μs or less (Load current : 5 mA or more), 0.1 ms or less (Load current : 0.5 mA or more) | 40 μs or less (Load current : 5 mA or more), 0.2 ms or less (Load current : 0.5 mA or more) | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | Open collector | | 24 V DC | 21.6 to 26.4 V DC | 0.2 A / point (Max. 14 per common terminal) | 1 μA or less | 0.2 V DC or less | | | 21.6 to 26.4 V DC | 35 mA or less | Zener diode | Photocoupler |
| | Relay symbol / Cyclic operation | 16 points [Input : 8, Transistor output : 8] | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | 4 points (50 kHz max. each) 2 channels can be controlled individually. (Note: For the limitations while operating units, reter to the manual.) | 4 points (6 Hz to 4.8 kHz) | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 8 points / common | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 20 μs or less (Load current : 5 mA or more), 0.1 ms or less (Load current : 0.5 mA or more) | 40 μs or less (Load current : 5 mA or more), 0.2 ms or less (Load current : 0.5 mA or more) | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | Open collector | | 5 to 24 V DC | 4.75 to 26.4 V DC | 0.2 A / point (Max. 14 per common terminal) | 1 μA or less | 0.2 V DC or less | | | 21.6 to 26.4 V DC | 30 mA or less | Zener diode | Photocoupler |
| | Relay symbol / Cyclic operation | 14 points [Input : 8, Relay output : 6] | Max. 62 points (Note: For the limitations while operating units, reter to the manual.) | Max. 110 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | One RS485 port is mounted (3P terminal block) Transmission speed (Baud rate) : 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance : 1,200 m 3,937 ft, Communication method : half duplex | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 4 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |
| | Relay symbol / Cyclic operation | 14 points [Input : 8, Relay output : 6] | Max. 62 points (Note: For the limitations while operating units, reter to the manual.) | Max. 110 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | One RS-232C port is mounted (3P terminal block) Transmission speed (Baud rate) : 2,400 to 115,200 bits/s, Transmission distance : 15 m 9.843 ft. Communication method : half duplex | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 4 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |
| | Relay symbol / Cyclic operation | 14 points [Input : 8, Relay output : 6] | Max. 62 points (Note: For the limitations while operating units, reter to the manual.) | Max. 110 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 4 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |
| | Relay symbol / Cyclic operation | 10 points [Input : 6, Relay output : 4] | Max. 58 points (Note: For the limitations while operating units, reter to the manual.) | Max. 106 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 2 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |
| | Relay symbol / Cyclic operation | 16 points [Input : 8, Transistor output : 8] | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | Max. 112 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | 4 points (50 kHz max. each) 2 channels can be controlled individually. (Note: For the limitations while operating units, reter to the manual.) | 4 points (6 Hz to 4.8 kHz) | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | One RS485 port is mounted (3P terminal block) Transmission speed (Baud rate) : 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance : 1,200 m 3,937 ft, Communication method : half duplex | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 8 points / common | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 20 μs or less (Load current : 5 mA or more), 0.1 ms or less (Load current : 0.5 mA or more) | 40 μs or less (Load current : 5 mA or more), 0.2 ms or less (Load current : 0.5 mA or more) | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | Open collector | | 5 to 24 V DC | 4.75 to 26.4 V DC | 0.2 A / point (Max. 14 per common terminal) | 1 μA or less | 0.2 V DC or less | | | 21.6 to 26.4 V DC | 30 mA or less | Zener diode | Photocoupler |
| | Relay symbol / Cyclic operation | 14 points [Input : 8, Relay output : 6] | Max. 62 points (Note: For the limitations while operating units, reter to the manual.) | Max. 110 points (Note: For the limitations while operating units, reter to the manual.) | EEPROM (no backup battery required) | 16 k steps | 110 approx. | 210 approx. | Basic instructions : 0.08 μs min. Timer instructions : 2.2 μs min. High-level instructions : 0.32 μs (MV instruction) min. | Basic instructions : 0.58 μs min. Timer instructions : 3.66 μs min. High-level instructions : 1.62 μs (MV instruction) min. | 4,096 points | 1,024 points | 12,315 words | 14 words (IO to ID) | 256 words | 256 labels | Equivalent to the program capacity | 1,000 stages | 500 subroutines | Single-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.) | Not available | Not available | Total 8 points (with high speed counter) | Input : 8 programs (6 programs for C10 only) / Periodic : 1 program / Pulse match : 4 programs/td> | In units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec. | In units of 0.5 ms : 0.5 ms to 600 ms | | | Stored program and system register in EEPROM | Stored fixed area in EEPROM Counter : 16 points Internal relay : 128 points Data register : 315 words | Watchdog timer (690 ms approx.), Program syntax check | Not available | Rewriting in RUN mode, Download in RUN mode (incl. comments), 8-character password setting, and Program upload protection | 24 V DC | 20.4 to 28.8 V DC | 5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher) | 0 to +55 ℃ 32 to +131 ℉ | -40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | 10 to 95% RH (at 25 ℃ 77 ℉, no condensation) | Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) / Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) / Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute | Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) / Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum | 5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions | 147 m/s2 or more , 4 times each in X, Y, and Z directions | 1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal) | Free from corrosive gasses and excessive dust | 24 V DC | 21.6 to 26.4 V DC | 2.6 mA approx. (at 24 V DC) | 9.1 kΩ approx. | 4 points / common + 1 point / common + 1point / comon | 19.2 V / 2 mA | 2.4 V / 1.2 mA | 10 ms approx. | 8 ms approx. | Photocoupler | Since the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program. | 1a | 2 A 250 V AC, 2 A 30 V DC (4.5 A / common) | | | | | | 2 x 107 operations or more | 105 operations or more | | | None | |