FP7

The FP7 Series offers high performance and functionality in a compact design. Advanced features and expandable intelligent units make it an ideal choice for various Industrial Automation applications.

Key Features

  • Connect Up To 64 Different Expansion Units
  • Add On Cassettes Expands Functionality (Communication And Analog I/O) Without Increasing Footprint
  • 24V, 5V DC Terminals And A RS232 Communication Port On All CPUs
  • Built-In Ethernet Port Supports Modbus TCP, MEWTOCOL, And Ethernet/IP Implicit Messaging. Up To 272 Connections Can Be Active Simultaneously
  • Fieldbus Units Available: Profibus, Profinet, CANOpen, DeviceNet, and EtherCAT Motion Controller
  • Built-In Webserver With Preset System Webpage
  • Up To 35 Serial Communication Channels Are Possible
  • SD Data Logging Capability (Up To 32GB)
  • HTTP And FTP Client Functions (SSL-Compatible)

Part Number List

Results 10
Models table for series FP7
Part No.DatasheetMemory Capacity: Memory Selection Pattern 1 Memory Capacity: Memory Selection Pattern 2 Memory Capacity: Memory Selection Pattern 3 Memory Capacity: Memory Selection Pattern 4Memory Capacity: Memory Selection Pattern 5 Programming MethodMethod Program MemoryOperation Speed External Input (X)External Output (Y)Internal Relay (R)System Relay (SR)Link Relay (L)Timer (T)Counter (C) (C)Link Data Register (LD)System Data Register (SD)Index Register (I0 to IE) Master Control Relay (MCR)Number of Labels (LOOP)Differential PointsNumber of Step LaddersNumber of Subroutines Number of Interrupt Program SD Memory Card FunctionReal Time ClockBattery Life (Value Applies When No Power Is Supplied At All.)Safety FunctionPLC Link FunctionInterfaceTransmission Distance Transmission Speed Communication MethodSynchronous Method Transmission FormatData Transmission Order:5V:24VCommunication InterfaceCommunication SpeedBer Of NodesTotal Cable LengthBer Of Simultaneous ConnectionsCommunication Protocol (Communication Layer)DNSDHCP/DHCPV6FTP Server/Client (SSL Compatible)HTTP Server/Client (SSL Compatible)SMTP Client (SSL Compatible) SNTPGeneral-Purpose CommunicationDedicated CommunicationAmbient TemperatureAmbient HumidityBreakdown VoltageInsulation Resistance Vibration ResistanceNoise ImmunityShock ResistanceOperating ConditionRated Voltage RangeCurrent ConsumptionNet Weight
Program (steps): 234,000
Data register (Note) : 65,536
Number of max. program block (PB): 468
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500
Data register (Note) : 131,072
Number of max. program block (PB): 443
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000
Data register (Note 1): 262,144
Number of max. program block (PB): 392
(Note) The factory default setting is pattern 3.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500
Data register (Note) : 524,288
Number of max. program block (PB): 289
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500
Data register (Note) : 999,424
Number of max. program block (PB): 103
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points
(Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits / sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
Max. 254 units
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3
Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16
Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
(Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps): 234,000
Data register (Note) : 65,536
Number of max. program block (PB): 468
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 221,500
Data register (Note) : 131,072
Number of max. program block (PB): 443
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 196,000
Data register (Note 1): 262,144
Number of max. program block (PB): 392
(Note) The factory default setting is pattern 3.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 144,500
Data register (Note) : 524,288
Number of max. program block (PB): 289
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 51,500
Data register (Note) : 999,424
Number of max. program block (PB): 103
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns / step
8,192 points
(Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I / O points. When I / O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits / sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
Max. 254 units
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3
Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16
Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
(Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps): 121,500
Data register (Note 1): 131,072
Number of max. program block (PB): 243
(Note) The factory default setting is pattern 1.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000
Data register (Note) : 262,144
Number of max. program block (PB): 192
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000
Data register (Note) : 425,984
Number of max. program block (PB): 128
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000
Data register (Note) : 589,824
Number of max. program block (PB): 64
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits/sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
Max. 254 units
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3
Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16
Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
(Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps): 121,500
Data register (Note 1): 131,072
Number of max. program block (PB): 243
(Note) The factory default setting is pattern 1.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000
Data register (Note) : 262,144
Number of max. program block (PB): 192
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000
Data register (Note) : 425,984
Number of max. program block (PB): 128
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000
Data register (Note) : 589,824
Number of max. program block (PB): 64
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits/sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps): 121,500
Data register (Note 1): 131,072
Number of max. program block (PB): 243
(Note) The factory default setting is pattern 1.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000
Data register (Note) : 262,144
Number of max. program block (PB): 192
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000
Data register (Note) : 425,984
Number of max. program block (PB): 128
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000
Data register (Note) : 589,824
Number of max. program block (PB): 64
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits/sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
Ethernet 100BASE-TX / 10BASE-TX
100 Mbps, 10 Mbps auto negotiation function
Max. 254 units
100 m 328 ft (500 m 1,640 ft when a repeater is used)
Max. 220 connections (user connection: 216, system connection: 4)
TCP / IP, UDP
Supports name servers
Automatic IP address acquisition
Server function, file transfer, number of user: 3
Client function, data and file transfer
Server function, system web, Customer web (8 MB), number of concurrent session: 16
Client function, data transfer
Client function, mail transfer
Time adjustment function
16 kB / 1 connection (user connection: 1 to 16)
Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note))
(Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps): 121,500
Data register (Note 1): 131,072
Number of max. program block (PB): 243
(Note) The factory default setting is pattern 1.
(Note 1) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 96,000
Data register (Note) : 262,144
Number of max. program block (PB): 192
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 64,000
Data register (Note) : 425,984
Number of max. program block (PB): 128
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps): 32,000
Data register (Note) : 589,824
Number of max. program block (PB): 64
(Note) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 11 ns/step
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
SDHC memory cards of up to 32 GB are usable.
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit )
Password / Restricted distribution / Read disable setting / Encryption
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits/sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
(Note) 5 V and 24 V DC types are not usable at the same time.
For 24 V DC type GT series Programmable Display
(Note 1) 5 V and 24 V DC types are not usable at the same time.
(Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display.
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MOhm or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
200 mA or less
220 g approx. (with terminal block and end unit)
Program (steps)(Note) : 64,000
Data register (words)(Note) : 131,072
Number of max. program block (PB) : 128
(Note) The factory default setting is pattern 1.
(Note) For data register (DT), data up to 262,144 words can be backed up.
Program (steps)(Note) : 32,000
Data register (words)(Note) : 262,144
Number of max. program block (PB) : 64
(Note1) For data register (DT), data up to 262,144 words can be backed up.
Relay symbol method
Cyclic operation method
Built-in flash ROM (no backup battery required)
Basic instruction: min. 14 ns/step
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
8,192 points
(Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays.
32,768 points
Indicate operation status of various relays is shown.
16,384 points
4,096 points: Timer capable of counting (units: 10 μs, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295
1,024 points, Counter capable of counting 1 to 4,294,967,295
16,384 words
Internal operation status of various registers is shown.
15 long words / With switching function
Unlimited
Max. 65,535 points for each program block (PB)
Unlimited
Unlimited
Max. 65,535 points for each program block (PB)
1 periodical interrupt program
Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week
(Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month
Max. 16 units, link relays: 1,024 points, link registers: 128 words.
(Data transfer and remote programming are not supported)
(Link area allocation is switchable between the first and the second half)
RS-232C, three-wire system, 1 channel
(Note) SD, RD and SG terminals are isolated from internal circuits.
15 m 49.213 ft
300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200, 230,400 bits/sec,
Half-duplex system
Start-stop synchronization system
Stop bit: 1 bit / 2 bits
Parity: none / odd / even
Data length: 7 bits / 8 bits
Start code: with STX / without STX
End code: CR / CR + LF / none / ETX
Transmit from bit 0 in character units.
For 5 V DC type GT series Programmable Display
0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉
10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation)
500 V AC for 1 minute
100 MΩ or more (at 500 V DC)
5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions
1,000 V [p-p] with pulse width 50 ns and 1 μs (using a noise simulator)
147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2)
Free from corrosive gasses and excessive dust
20.4 to 28.8 V DC
150 mA or less
180 g approx. (with terminal block and end unit)