Specification

Specifications table for model ER-F12SA
ItemPerformance characteristics
CE Marking Compliant DirectivesEMC Directive, RoHS Directive
Charge Removal Time1.5 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ion Balance±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Supply Voltage 24 V DC ±10%
Current Consumption400 mA or less
Discharge MethodHigh-frequency AC method
Discharge Output Voltage± 2 kV approx.
Main FunctionsError output, Discharge halt input
IndicatorDischarge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone Generation0.04 ppm or less
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ambient Temperature0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage : -10℃ to +65℃ +14℉ to +149℉
Ambient Humidity35% RH to 65% RH (No dew condensation allowed),
Storage : 35% RH to 65% RH
Grounding MethodC (capacitor) grounding
MaterialEnclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC
Weight (Typ.)New weight : 790 g approx.
AccessoriesStraight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc.
(Note): The discharge needle unit is loaded on the straight louver before shipment.
RemarkIf not specified, the ambient temperature for measurement is +20℃ +68℉.