Specification

Specifications table for model ER-VW
ItemPerformance characteristics
CE Marking Compliant DirectivesEMC Directive, RoHS Directive
Charge Removal Time1 sec. or less (plus or minus1,000 V to plus or minus100 V)
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ion Balanceplus or minus10 V or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ozone Generation0.05 ppm or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa.
Applicable FluidAir (dried clean air)
(Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ℉) and an air filter (mesh size around 0.01 microm 0.0004 mil).
Supplied Air Flow 60 liter/min. (ANR) or less
Air Pressure Range0.05 to 0.5 MPa
Supply Voltage 24 V DC plus or minus 10 %
Current Consumption120 mA or less
Discharge MethodHigh frequency AC method
Discharge Output Voltage2,000 V approx.
Output [Check Error Discharge (DSC)]NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
(Note:"DSC" is an abbreviated name of "DISCHARGE".)
Output: Output Operation Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normal
Error output (ERROR): OFF when abnormal discharge is detected, ON when operation is normal
Discharge output (DSC) (Note): ON when discharging, OFF when discharge halts
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Output: Short-Circuit ProtectionIncorporated
Discharge Halt Input (DSC OFF)Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)
(Note:"DSC" is an abbreviated name of "DISCHARGE".)
Reset Input In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR
Indicators: Power Green LED (lights up when the power is ON)
Indicators: Discharge (DSC)Green LED (lights up when discharging)
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Indicators: Air Monitoring (Air)Orange LED (lights up when no air is being supplied)
(Note) Discharge halts when lights up.
Indicators: Check Orange LED (lights up when the discharge needle is dirty or worn, etc.)
Indicators: Error (Error)Red LED (lights up when abnormal discharge is detected)
Ambient Temperature0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉
Ambient Humidity35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH
I/O ConnectorFor power & input / output: 8-pin connector, For connection: 9-pin connector
Connectable UnitsMaximum number of connectable units: 5 (Including this unit)
Enclosure EarthingCapacitor earth
MaterialEnclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten
Weight (Typ.)Net weight: 110 g approx., Gross weight: 180 g approx.
AccessoriesConnector attached cable: 1 pc. (length 0.5 m 1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc.

Stock Check