| | 120 A | 12 V DC | Flux-resistant | Single side stable | PC board terminal (wide blade) | Min. 10.5 mm (Clearance and Creepage) (Initial) | Min. 3.6 mm (Initial) | 10 | Max. 75% V of rated coil voltage (Initial) | 50 | Min. 5% V of rated coil voltage (Initial) | 208 mA | 57.6 Ω | 2,500 mW | 110% V of rated coil voltage (at 55°C) | 1 Form A | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | 58,800 VA (AC), 7,200 W (DC) | 120 A 490 V AC, 120 A 60 V DC | AgNi type | 800 V AC, 60 V DC | 120 A (AC, DC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | 40 to 100% V (at -40~55°C) 50 to 60% V (at 55~85°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 115 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 55 A 800 V AC Min. 10x103 ope. 90 A 490 V AC Min. 103 ope. 120 A 490 V AC
[switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 120 A 60 V DC |
| | 120 A | 9 V DC | Flux-resistant | Single side stable | PC board terminal (wide blade) | Min. 10.5 mm (Clearance and Creepage) (Initial) | Min. 3.6 mm (Initial) | 10 | Max. 75% V of rated coil voltage (Initial) | 50 | Min. 5% V of rated coil voltage (Initial) | 278 mA | 32.4 Ω | 2,500 mW | 110% V of rated coil voltage (at 55°C) | 1 Form A | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | 58,800 VA (AC), 7,200 W (DC) | 120 A 490 V AC, 120 A 60 V DC | AgNi type | 800 V AC, 60 V DC | 120 A (AC, DC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | 40 to 100% V (at -40~55°C) 50 to 60% V (at 55~85°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 115 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 55 A 800 V AC Min. 10x103 ope. 90 A 490 V AC Min. 103 ope. 120 A 490 V AC
[switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 120 A 60 V DC |
| | 120 A | 6 V DC | Flux-resistant | Single side stable | PC board terminal (wide blade) | Min. 10.5 mm (Clearance and Creepage) (Initial) | Min. 3.6 mm (Initial) | 10 | Max. 75% V of rated coil voltage (Initial) | 50 | Min. 5% V of rated coil voltage (Initial) | 417 mA | 14.4 Ω | 2,500 mW | 110% V of rated coil voltage (at 55°C) | 1 Form A | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | 58,800 VA (AC), 7,200 W (DC) | 120 A 490 V AC, 120 A 60 V DC | AgNi type | 800 V AC, 60 V DC | 120 A (AC, DC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | 40 to 100% V (at -40~55°C) 50 to 60% V (at 55~85°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 115 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 55 A 800 V AC Min. 10x103 ope. 90 A 490 V AC Min. 103 ope. 120 A 490 V AC
[switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 120 A 60 V DC |
| | 120 A | 24 V DC | Flux-resistant | Single side stable | PC board terminal (wide blade) | Min. 10.5 mm (Clearance and Creepage) (Initial) | Min. 3.6 mm (Initial) | 10 | Max. 75% V of rated coil voltage (Initial) | 50 | Min. 5% V of rated coil voltage (Initial) | 104 mA | 230 Ω | 2,500 mW | 110% V of rated coil voltage (at 55°C) | 1 Form A | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | 58,800 VA (AC), 7,200 W (DC) | 120 A 490 V AC, 120 A 60 V DC | AgNi type | 800 V AC, 60 V DC | 120 A (AC, DC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | 40 to 100% V (at -40~55°C) 50 to 60% V (at 55~85°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 115 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 55 A 800 V AC Min. 10x103 ope. 90 A 490 V AC Min. 103 ope. 120 A 490 V AC
[switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 120 A 60 V DC |