High Capacity. Low Power Consumption.

Panasonic's HE-N Series General Power Relays feature high switching capacity of 120A @ 480VAC or 55A @ 800VAC in a 1 Form A (SPST-NO) contact arrangement. These Power Relays offer a compact size of 50mm x 40mm x 43mm which can be mounted on a PC Board without screw terminals for easier design and faster board assembly.

HE-N Series General Power Relays also have a large contact gap of 3.6mm which is a requirement for solar inverter applications. These Relays are well suited for many energy management applications with low power consumption and only 400mW coil holding power.

Features of the HE-N Series

  • High Capacity Contact Rating: 120A @ 480VAC (1,000 Cycles N.O.) Or 55A @ 800VAC (10,000 Cycles N.O.)
  • Compact 50mm x 40mm x 43mm Case Size
  • PCB Mounted
  • Low 400mW Coil Holding Power
  • Large 3.6mm Contact Gap And 10.5mm Insulation Distance
  • RoHS/REACH Compliant

Benefits

  • High-Capacity
  • Takes up Less Board Space
  • Easier Assembly for High Volume Projects
  • Low Power Operation
  • Meets IEC 61810-1
  • Environmentally Friendly
Series image for HE-N Series Relays

HE-N Series Relays

Part number list

Results 4
Models table for series HE-N Series Relays
Part No.DatasheetContact TypeRated Coil VoltageProtective ConstructionOperating Function Terminal TypeInsulation DistanceContact GapPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage Contact ArrangementContact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilCoil Holding VoltageOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
120 A
12 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
208 mA
57.6 Ω
2,500 mW
110% V of rated coil voltage (at 55℃)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value)
AgNi type
120 A 490 V AC, 120 A 60 V DC
58,800 VA (AC), 7,200 W (DC)
800 V AC, 60 V DC
120 A (AC, DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
40 to 100% V (at -40~55℃)
50 to 60% V (at 55~85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85℃
(When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 115 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s]
Min. 10x103 ope. 55 A 800 V AC
Min. 10x103 ope. 90 A 490 V AC
Min. 103 ope. 120 A 490 V AC

[switching frequency ON : OFF = 1 s : 9 s]
Min. 103 ope. 120 A 60 V DC
120 A
9 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
278 mA
32.4 Ω
2,500 mW
110% V of rated coil voltage (at 55℃)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value)
AgNi type
120 A 490 V AC, 120 A 60 V DC
58,800 VA (AC), 7,200 W (DC)
800 V AC, 60 V DC
120 A (AC, DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
40 to 100% V (at -40~55℃)
50 to 60% V (at 55~85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85℃
(When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 115 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s]
Min. 10x103 ope. 55 A 800 V AC
Min. 10x103 ope. 90 A 490 V AC
Min. 103 ope. 120 A 490 V AC

[switching frequency ON : OFF = 1 s : 9 s]
Min. 103 ope. 120 A 60 V DC
120 A
24 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
104 mA
230 Ω
2,500 mW
110% V of rated coil voltage (at 55℃)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value)
AgNi type
120 A 490 V AC, 120 A 60 V DC
58,800 VA (AC), 7,200 W (DC)
800 V AC, 60 V DC
120 A (AC, DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
40 to 100% V (at -40~55℃)
50 to 60% V (at 55~85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85℃
(When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 115 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s]
Min. 10x103 ope. 55 A 800 V AC
Min. 10x103 ope. 90 A 490 V AC
Min. 103 ope. 120 A 490 V AC

[switching frequency ON : OFF = 1 s : 9 s]
Min. 103 ope. 120 A 60 V DC
120 A
6 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
417 mA
14.4 Ω
2,500 mW
110% V of rated coil voltage (at 55℃)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
Max. 3 mΩ (by voltage drop 5 V DC 120 A, reference value)
AgNi type
120 A 490 V AC, 120 A 60 V DC
58,800 VA (AC), 7,200 W (DC)
800 V AC, 60 V DC
120 A (AC, DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
40 to 100% V (at -40~55℃)
50 to 60% V (at 55~85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85℃
(When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 115 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s]
Min. 10x103 ope. 55 A 800 V AC
Min. 10x103 ope. 90 A 490 V AC
Min. 103 ope. 120 A 490 V AC

[switching frequency ON : OFF = 1 s : 9 s]
Min. 103 ope. 120 A 60 V DC