Item | Performance characteristics |
---|---|
Rated Coil Voltage | 12V DC |
Contact Arrangement | 1 Form A |
Contact Capacity | 250 A |
Protective Construction | Capsule contact |
Terminal Type | Screw terminal |
Operating Function | Single side stable |
Operate (Set) Voltage (at20°C) (Initial) | Max. 9 V DC |
Release (Reset) voltage (at20℃) (Initial) | Min. 0.5 V DC |
Rated Operating Current [±10%] (at 20°C) | 0.5 A |
Coil Resistance (At 20oC) | 24Ω |
Rated Operating Power (at 20°C) | 6.0 W |
Max. applied voltage | 16 V DC |
Contact Material | Cu alloy |
Nominal Switching Capacity (Resistive Load) | 250A 500V DC (Carry, 50mm2 wire) |
Max. Carring Current | 250 A continuous (50mm2 wire) |
Min. Switching Load (Resistive) | 1 A 12V DC (at 20°C) |
Contact Voltage Drop (Initial) | Max. 0.125 V (250A carry current) |
Short Circuit Capacity | 8,000 A (at Max. 5 ms), No smoke and no ignition |
Insulation Resistance (Min. MΩ)(Initial) | Min. 100 MΩ (At 1000 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Between Open Contacts) (Initial) | 2,500 Vrms for 1min. (detection current: 10 mA.) |
Dielectric Strength (Between Contacts and Coil) (Initial) | 2,500 Vrms for 1min. (detection current: 10 mA.) |
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial) | Max. 50 ms (without bounce) |
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20°C) (Initial) | Max. 30 ms (with no coil protective elements) |
Shock Resistance: Functional | For ON: Min. 588 m/s2 (Half-sine shock pulse: 11 ms; detection time: 10 µs) For OFF: Min. 147 m/s2 (Half-sine shock pulse: 11 ms; detection time: 10 µs) |
Shock Resistance: Destructive | Min. 588 m/s2 (Half-sine shock pulse: 11 ms) |
Vibration Resistance: Functional | 10 to 200 Hz, 44.1 m/s2 (detection time: 10 µs) |
Vibration Resistance: Destructive | 10 to 200 Hz, 44.1 m/s2 X, Y, Z direction: 4 hours |
Expected Life: Mechanical Life | Min. 2 x 105 |
Expected Life: Switch-Off Life | 1,800 A 500 V DC, Min. 1 operation (No polarity) |
Expected Life: Inrush Current (Capacitor) | 140 A 20 V DC, Min. 70,000 operations |
Conditions | Ambient temperature: –40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing or condensation.) |
Weight (Typ.) | Approx. 400 g |
Standard Packing | 20 pcs (packed with 20pcs / 1 tray) |
Usable Voltage Range | 10 V DC to 16 V DC |