Specifications

Specifications table for model AEV18024
ItemPerformance characteristics
Terminal TypeScrew terminal
Coil Terminal StructureConnector
Rated Coil Voltage24V DC
Contact Capacity80 A
Protective ConstructionCapsule contact
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 18V DC
Release (Reset) voltage (at20℃) (Initial)Min. 2V DC
Rated Operating Current [±10%] (at 20°C)0.176 A
Coil Resistance (At 20oC)136Ω
Rated Operating Power (at 20°C) 4.2W
Max. applied voltage32V DC
Contact Arrangement1 Form A
Contact MaterialTungsten and copper alloys
Nominal Switching Capacity (Resistive Load) 80A 450V DC (Carry, 15mm2 wire)
Max. Carring Current 80A Continuity
120A 15 min.
180A 20 min. (15mm2 wire)
Min. Switching Load (Resistive) 1A 12V DC (at 20℃)
Contact Voltage Drop (Initial)Max. 0.067V (By Voltage drop 6V DC 20A)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Between Open Contacts) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Dielectric Strength (Between Contacts and Coil) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 50ms (without bounce)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 30ms (with no coil protective elements)
Shock Resistance: Functional For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Shock Resistance: DestructiveMin. 490 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance: Functional10 to 200 Hz, 43 m/s2 (detection time: 10 μs)
Vibration Resistance: Destructive10 to 200 Hz, 43 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 2 x 105
Expected Life: Electrical Life (Resistive)80A 450V DC, Min. 1,000 operations
Expected Life: Switch-Off Life[Forward direction]:
800A 300V DC, Min. 1 operation
120A 450V DC, Min. 50 operations
[Reverse direction]: -120A 200V DC, Min. 50 operations
Expected Life: Inrush Current (Capacitor)150A 20V DC, Min. 70,000 operations
ConditionsAmbient temperature: –40 to +80℃, Humidity: 5 to 85% RH (Avoid icing when using at temperatures lower than 0℃.)
Weight (Typ.)Approx. 400 g
Inner Carton (Pieces)1
Outer Carton (Pieces) 20
Usable Voltage Range20 to 32V DC

Stock check

Model image for AEV18024

AEV18024

Resources

Filter by:
Showing 1 to 10 of 13 results
Results13
Latest Videos

Playlist

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for NPI: SF-M Series Relays

NPI: SF-M Series Relays

Thumbnail for SF-M Series Safety Relays

SF-M Series Safety Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap