Panasonic’s DJ Series Polarized Power Relays are characterized by high switching capacity in a wide variety of contact arrangements, 1 Form A, 1 Form B, 1 Form C, 1 Form A 1 Form B, 2 Form A, 2 Form B, and 2 Form C. In addition, each one is available in 1-coil latching, 2-coil latching, or single side stable types. The DJ Series Relays are available with a test button option to facilitate circuit checks.

Features and Benefits

  • Compact With High Contact Rating
  • Variety Of Contact Arrangements
  • Latching Types Available
  • Low Power Consumption
  • Long Insulation Distance
  • Test Button For Operation Verification
  • Sealed Construction Option Allows Automatic Washing
  • UL, CSA, and TÜV Compliant

Applications

  • Industrial Machine
  • Electric Power Devices
  • Household Appliance Networks
  • Time Switches
Series image for DJ Series Relays

DJ Series Relays

Part number list

Results 205
Models table for series DJ Series Relays
Part No.DatasheetProtective ConstructionOperating Function Type ClassificationRated Coil VoltageRated Operating Power Contact ArrangementTerminal TypeInsulation DistancePacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Set Voltage Reset VoltageRated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Max. Allowable Voltage (at 20°C 68°F)Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
Flux-resistant
1 coil latching
With a test button
12 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 12.5 mA
Reset coil: 12.5 mA
Set coil: 960 Ω
Reset coil: 960 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
1 coil latching
Without a test button
6 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 25 mA
Reset coil: 25 mA
Set coil: 240 Ω
Reset coil: 240 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
1 coil latching
Without a test button
24 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 6.3 mA
Reset coil: 6.3 mA
Set coil: 3,840 Ω
Reset coil: 3,840 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Sealed
1 coil latching
Without a test button
5 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 29.9 mA
Reset coil: 29.9 mA
Set coil: 167 Ω
Reset coil: 167 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
1 coil latching
With a test button
48 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 3.1 mA
Reset coil: 3.1 mA
Set coil: 15,360 Ω
Reset coil: 15,360 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Sealed
2 coil latching
Without a test button
5 V DC
250 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 50 mA
Reset coil: 50 mA
Set coil: 100 Ω
Reset coil: 100 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
2 coil latching
Without a test button
12 V DC
250 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 20.8 mA
Reset coil: 20.8 mA
Set coil: 576 Ω
Reset coil: 576 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
2 coil latching
Without a test button
5 V DC
250 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 50 mA
Reset coil: 50 mA
Set coil: 100 Ω
Reset coil: 100 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Flux-resistant
1 coil latching
With a test button
24 V DC
150 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 6.3 mA
Reset coil: 6.3 mA
Set coil: 3,840 Ω
Reset coil: 3,840 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Sealed
2 coil latching
Without a test button
48 V DC
250 mW
1 Form C
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
100
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 5.2 mA
Reset coil: 5.2 mA
Set coil: 9,216 Ω
Reset coil: 9,216 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays